The height provision is the same for MDE used by patients in supine, prone, or side-lying positions (M301) and patients in seated positions (M302)....
Search Results "Non-Positive Shut Off"
-
5.1 Transfer Surface Height Recommendations
-
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
position and balance on diagnostic equipment used by patients in a standing position....
-
4. Organization of Technical Criteria
Medical diagnostic equipment is typically designed to support patients in certain positions....
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone, or side-lying position...
-
i. Medical examination and treatment tables and chairs
i. Medical examination and treatment tables and chairs Healthcare providers use examination and treatment tables and chairs for many different types of medical and dental...
-
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
5.7.1 Lift Compatibility Clearance in Base for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
-
M301.2.1 Height
The transfer surface is permitted to be positioned outside of the specified height range when not needed to facilitate transfer....
-
M301.2.1 Adjustability
A low transfer position at a height of 17 inches (430 mm) minimum and 19 inches (485 mm) maximum; B. A high transfer position at 25 inches (635 mm); and C....
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the...
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface.
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers. Transfer supports should be located along the long side of the transfer surface on the opposite side of the...
-
Section 37.71 Purchase or Lease of New Non-Rail Vehicles by Public Entities Operating Fixed Route Systems
Section 37.71 Purchase or Lease of New Non-Rail Vehicles by Public Entities Operating Fixed Route Systems This section generally sets out the basic acquisition requirements for a public...
-
M301.2.3 Transfer Surface Transfer Sides
The head and foot ends of the table are likely to have obstructions such as extraction handles, the gantry, or patient positioning devices....
-
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position
5.3.3 Transfer Sides for Equipment Used by Patients in Seated Position....
-
5.4.2 Transfer Support Length for M301 and M302
The purpose of a minimum length is to ensure that there is a minimum gripping surface available to support positioning and repositioning during a transfer....
-
Armrests M302.3.2
Armrests M302.3.2 Armrests are recommended but not required. If provided armrests cannot interfere with transfer supports during the transfer. Dual transfer support/armrest...
-
17 Inch Low Height
17 Inch Low Height A portion of the Committee maintained that a height range of 17 inches - 25 inches would accommodate a significant portion of people with disabilities. Data...
-
11B-208.1 General
trucks, other delivery vehicles, or vehicular impound shall not be required to comply with Section 11B-208 provided that lots accessed by the public are provided with a passenger drop-off...
-
A4.10.13 Car Position Indicators
A special button may be provided that would activate the audible signal within the given elevator only for the desired trip, rather than maintaining the audible signal in constant...
-
A4.10.13 CAR POSITION INDICATORS
A special button may be provided that would activate the audible signal within the given elevator only for the desired trip, rather than maintaining the audible signal in constant...
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....