require a completely clear opening in hospitals, institutions or public buildings Designed to swing door completely clear of the opening when door is opened 95° Consult factory for hinges...
Search Results "Hinge Side Clearance"
Commonly Searched Documents
- Stanley FBB 269 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 266 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 268 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
- Stanley FBB 264 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
407.4.3 Platform to Hoistway Clearance
407.4.3 Platform to Hoistway Clearance. The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum....
-
Doors at Entrances to Businesses
It may also be possible to use special "swing clear" hinges that provide approximately 1 1/2 inches more clearance without replacing the door and door frame....
-
5.3.3 Transfer Sides Recommendations for M302
transfer onto the short side and the long side of the surface....
-
R405.1 General
Clearances are measured in relation to the usable clear space, not necessarily to the vertical support for an element....
-
804.2 Clearance
804.2 Clearance. Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
305.7 Maneuvering Clearance
305.7 Maneuvering Clearance....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
804.2 Clearance
Where a pass through kitchen is provided, clearances shall comply with 804.2.1. Where a U-shaped kitchen is provided, clearances shall comply with 804.2.2....
-
Are side flares required at curb ramps?
The ADA Standards do not require that curb ramps have side flares, but limit the slope (1:10 max.) where they are provided....
- Hager Companies Three Knuckle - Full Mortise Swing Clear Hinge AB7001
-
Philips Healthcare
recommendations included in the Advisory Committee Report dated September 13th, 2013 represent the consensus of the committee With the following exceptions: 1) NPRM M303.2.4 Knee and Toe Clearance...
-
11B-306.2.5 Width
Toe clearance shall be 30 inches (762 mm) wide minimum. FIGURE 11B-306.2 TOE CLEARANCE...
-
11B-306.3.5 Width
Knee clearance shall be 30 inches (762 mm) wide minimum. FIGURE 11B-306.3 ‡‡ KNEE CLEARANCE...