Problem Two: The entrance door threshold is one inch high....
Search Results "Entry Door (FHA)"
Commonly Searched Documents
-
Problem Two (Entrance)
-
1013.4, Item 4
Each exit access door from an interior room or area to a corridor or hallway that is required to comply with Section 1013.1, shall be identified by a tactile exit sign with the words “EXIT...
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1010.1.9.7, Item 6.4 at doors with delayed egress locks shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
A. Accessible Voting Program
facilities and equipment (including, but not limited to, permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps, traffic cones, signs, wedges, and door...
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
-
Visual Alarms
Result: People who are deaf or hard of hearing cannot hear fire alarms, ringing telephones, knocking at doors or ringing doorbells....
-
Clear Floor Space [4.16.2]
Figure 28) specifies the amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor space at other provided fixtures, door...
-
Vertical Clearance [§307.4]
Vertical Clearance [§307.4] Headroom clearance of at least 80” high is required along all circulation paths (except at doors and doorways where a 78” minimum clearance is permitted to...
-
§ 38.57(b)
Particular attention shall be given to ensuring maximum maneuverability immediately inside doors. Ample vertical stanchions from ceiling to seat-back rails shall be provided....
- Lighthouse International
-
Library
Offset pivot hinge on door to library Large print books in the library Handrails at two height Evaporative cooler to save the energy used by air conditioners...
-
§ 38.101(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge plate, or...
-
Maintenance of Accessible Features
Entities should plan for these issues and modify operational policies as needed to provide accessible means of entry while the pool is open....
-
Paperwork Reduction Act
Under this rule, railroads that choose to use a means of meeting the performance standard other than level-entry boarding would have to submit a proposed plan to FRA or FTA demonstrating...
-
§382.63(a)(3)
(3) The lavatory shall provide door locks, accessible call buttons, grab bars, faucets and other controls, and dispensers usable by qualified individuals with a disability, including wheelchair...
-
Head Room [4.3.5]
Eighty-inch doors, including those equipped with closers, are considered acceptable under this requirement....
-
Elevator Car Requirements [§407.4]
Alternative configurations that provide unobstructed wheelchair turning space (60” diameter circle or T-turn) with the doors closed are permitted....
-
§ 38.119(a)
(a) Any stepwell, or doorway with a lift, ramp or bridge plate, shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread, ramp, bridge plate...
-
§ 38.81(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the...
- Carr Corporation Folding Work Desk/Charting Stations
- GameTime ADA Wide Ramp Attachment 3D
- Harmar EPL Enclosed Vertical Platform Lift
-
Press Boxes: ADA Standard Section 206.2.7
Section 206.2.7 covers scoping requirements in the most current ADA Standards for accessible routes to press boxes.
-
Clear Floor or Ground Space: ADA Standard Section 1008.4.2
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....