In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
Search Results "Entry Door (FHA)"
-
11B-608.3.3 Alternate roll-in type shower compartments
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries....
-
11B-804.2.1 Pass through kitchen
Pass through kitchens shall have two entries....
- Elvoron LU/LA - Limited Use / Limited Application Hydraulic Elevator
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level....
-
11B-407.2.3.1 Floor designation
A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level....
-
4.13.8* Thresholds at Doorways
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
4.13.8* THRESHOLDS AT DOORWAYS
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
216 Signs
Exceptions: Exterior signs that are not located at the door to the space they serve shall not be required to comply with 703.2. New: Requirement for exterior signs....
-
16. Modification to be completed within six months
Modifications to be completed within six months: As agreed between the parties, within six months of the date of entry of this Consent Decree, Defendants shall make the following physical...
-
Site Constraints
An example might include construction of a new infill building with a historic facade which must be maintained (thus predetermining the entry floor level) and where space for a ramp is not...
-
11B-608.2.3 Alternate roll-in type shower compartments
A 36 inch (914 mm) wide minimum entry shall be provided at one end of the long side of the compartment....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
4. Pressure Gauge
Many people with disabilities have limitations on the amount of force they can exert to open a door or operate a device that requires pushing or pulling....
-
1133B.2.5.2
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.5.2 Hand-activated door opening hardware, handles, pulls, latches, locks and...
-
III-4.4300 Standards to apply
However, because of space constraints, he is unable to widen the door to the full 32-inch clearance required for alterations under ADAAG....
-
1010.1.9.8.1 Delayed egress locking system
Initiation of the irreversible process shall activate an audible signal in the vicinity of the door....
-
1013.4 Raised character and braille exit signs
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.” 2....
- Hill-Rom Uno™ 102 Patient Lift
-
O. Accessible Portable Toilets
For the entrance to an accessible portable toilet to be usable, there must either be no step or a ramp must be installed that extends extends from the hinge side of the door to at least...
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches....
-
11B-216.8.3 Signs at toilet and urinal compartments
Exception: A sign with tactile characters shall be permitted on an in-swinging and self-closing door at compartments not required to comply with Section 11B-604 or Section 11B-605.5....