General: The California Building Code indicates technical criteria for detectable warning surfaces (truncated domes)....
Search Results "Surface Smoothness"
Commonly Searched Documents
-
DSA IR 11B-4: DETECTABLE WARNINGS (with revisions issued through Nov. 2011)
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
1011.4.2 Wheelchair Space
Picnic tables shall provide at least one wheelchair space for each 24 linear feet (7320 mm) of usable table surface perimeter. ...
-
7(2)(b)(iv)
The other (non-grab bar) side of the toilet fixture is a minimum of 1'3" from the finished surface of adjoining walls, vanities or from the edge of a lavatory. (See Figure 7(a).)...
-
704.5 TTY Shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
1017.10 Trailhead Signs
This section requires trail information signs at trailheads to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and...
-
4.34.6.6* RANGES AND COOKTOPS
If ovens or cooktops have knee spaces underneath, then they shall be insulated or otherwise protected on the exposed contact surfaces to prevent burns, abrasions, or electrical shock....
-
1011.4.2 Wheelchair Space
Picnic tables shall provide at least one wheelchair space for each 24 linear feet (7320 mm) of usable table surface perimeter....
-
GRADE (Adjacent Ground Elevation)
[DSA-AC & HCD 1-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property...
-
§ 38.31(c)
doorways, including doorways in which lifts or ramps are installed, shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination on the street surface...
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back of the curb on the ramp surface...
-
GRADE (Adjacent Ground Elevation)
[DSA-AC & HCD 1-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property...
-
Jean Tessmer
It is an excellent tool for laying out and placement of ADA routes, ramps, landings, random directional surfaces, and curb ramps. 1oo% compliance can be achieved when using the sliding...
- Milgard® SmartTouch™ Window Lock
-
Picnic Tables
All new picnic table installations must comply with requirements for accessible seating spaces, table clearance, slope, and surface....
-
Common Requirements (R304.5) (Section-by-Section Analysis)
Grade breaks are not permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks must be flush....
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M305.2.1 would require the transfer supports to be located within reach of the transfer surface and not obstruct transfer onto the surface when in position....
-
Clearance in Base (M301.4.1 and M302.4.1)
would require the clearance in the base to be 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination surface...
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....