(c) The doorways of vehicles not operating at lighted station platforms shall have outside lights which provide at least 1 foot-candle of illumination on the station platform or street surface...
Search Results "Surface Smoothness"
Commonly Searched Documents
-
§ 38.81(c)
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Industry Standards
Test Method for Determining Floor Tolerances Using Waviness, Wheel Path and Levelness Criteria (Metric) ASTM F 802-83(2003) Standard Guide for Selection of Certain Walkway Surfaces...
-
4. Organization of Technical Criteria
For example, X-ray equipment that is designed for use in a standing position for certain procedures would have to meet the technical criteria for slip resistant standing surface and standing...
-
218 and 810 Transportation Facilities
Detectable warnings provide a distinctively textured surface of truncated domes....
-
QUESTION: WHAT CONSTITUTES AN ALTERATION TO A PLATFORM FOR PURPOSES OF TRIGGERING THE APPLICATION OF SECTION 37.42 REQUIREMENTS?
For example, if the platform height relative to the top of rail is raised, if the old surface is removed and/or a new surface put down, or if there is a reconstruction of or structural change...
-
Scoping [4.1.2(1), 4.1.3(1)] and Location [4.3.2]
Clear width, surface texture, running and cross slope, and the treatment of changes in level help determine the usability of walking surfaces by people with mobility impairments....
-
1016.5 Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on outdoor recreation access routes can be obstacles....
-
Clearance Around Base (M301.4.2 and M302.4.2)
M302.4.2 would require the base of the equipment to provide a clearance 6 inches high minimum measured from the floor and 36 inches deep minimum measured from the edge of the examination surface...
-
§ 38.159(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches (32 mm) and 11/2 inches (38 mm) or shall provide an equivalent grasping surface, and have eased edges with corner radii...
-
§ 38.29(b)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
- Moen M–Dura Chrome Two-Handle Kitchen Faucet 8225SM
- Moen M–DURA Chrome Two-Handle Lavatory Faucet 8215SM
- Moen M–DURA Chrome Two-Handle Lavatory Faucet 8225SMF15
- Moen M–Dura Chrome One-Handle Multi-Purpose Faucet 8125
- Moen M–Dura Chrome One-Handle Multi-Purpose Faucet 8138
- Moen M–Dura Chrome One-Handle Kitchen Faucet 8711
- Moen M–Dura Chrome One-Handle Kitchen Faucet 8707
- Moen M–DURA Chrome Two-Handle Lavatory Faucet 8210SM
- Moen M–Dura Chrome One-Handle Kitchen Faucet 8713
- American Specialties Snap Flange Concealed Mounting Grab Bar 3700-Series
- Harmar CPL800H-1400H Hydraulic CPL with Modular Tower
- Moen M–Dura Chrome One-Handle Kitchen Faucet 8714