Outdoor constructed features can be confined on all or part of three sides by surfaces that are not firm and stable or that have changes in level....
Search Results "Side Transfer Surface"
-
1011.2.1 Size and Location
- Whitehall Manufacturing Surface Mounted Ligature Resistant Auto-Release Toilet Paper Holder
-
Tent Pads and Tent Platforms
Provide a minimum 48-inch (1,220-millimeter) clear floor or ground space on all sides of tents on tent pads and platforms that are required to be accessible....
- American Specialties Dual Roll Surface Mounted Toilet Paper Holder 7305-2
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS Current accessibility standards and regulations generally consider a transfer surface...
- Willoughby Industries WAW-2333 AquaWave® Three Station Solid Surface Lavatory System
- Willoughby Industries WAW-2322 AquaWave® Two Station Solid Surface Lavatory System
-
BENEFITS AND COSTS: OVERVIEW
BENEFITS AND COSTS: OVERVIEW Based on our analysis, we determined that transfer surface height requirements lower than 19 inches would increase the cost of designing and manufacturing...
- AJW Architectural Products U117 12 oz. Bright Liquid Soap Dispenser - Surface Mounted
- Mockett DH2 Door Handle Installation
-
Openings, Width and Length of Wheelchair Space
Wheelchair spaces must have a clear width of 30 inches minimum and a clear length of 48 inches minimum, measured to at least 9 inches above the floor surface....
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
R208.2 Where Not Required
Detectable warning surfaces are not required at cut-through pedestrian refuge islands that are less than 1.8 meters (6.0 ft) in length because detectable warning surfaces must extend 610...
-
4.2 Stretchers
They are best known as transport devices for patients in supine, prone, or side-lying positions....
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
-
Room Dimensions
An important consideration is whether or not space for side transfers is provided....
- AJW Architectural Products U592 1.6 Gallon Sanitary Napkin Disposal w/ Keyed Access Panel & Mounted Shelf - Surface Mounted
-
Clear Ground Space [1011.2]
The technical requirements include specific provisions for the size, location, surface, slope, and openings in the clear ground space....
-
NOTES
Note that height measurement, as defined by the tables and chairs subcommittee, represents the highest point of the transfer surface, inclusive of bolsters, when measuring to the top of...