Where a parallel approach is provided, the distance from the edge of the telephone enclosure to the face of the telephone unit shall be 10 inches (254 mm) maximum....
Search Results "Unit of Measurement"
-
11B-704.2.1.1 Parallel approach
-
11B-602.5 Spout location
The spout shall be located 15 inches (381 mm) minimum from the vertical support and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
BACKGROUND
Plaintiff United States of America (“United States”) commenced this action against Defendants Employees’ Retirement Systems of Alabama, Teachers’ Retirement Systems of Alabama (collectively...
- Corbin Russwin Inc. DC62900 Series Electromechanical Closer-Holder
-
Vehicle Parking
Design Tip Determine parking requirements for walk-in camping units....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
Urinal Depth
In the proposed rule, the Board sought to clarify the requirement in the original ADAAG that accessible urinals have an "elongated" rim by specifying a minimum dimension of 13 ½ inches, measured...
-
502.6 Identification
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [ECTCR UFAS 4.6.4] Advisory 502.6 Identification....
-
Cross Slope
Once placed in the water, measurements, absent live loads, are to be made from a static condition (i.e., absence of movement that results from wind, waves, etc.)....
-
R302.6 Cross Slope
The cross slope of the pedestrian access route is measured perpendicular to the direction of pedestrian travel....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
-
Surface Textures [4.3.6]
Since there are no uniform test procedure or measurable values for these characteristics (except for slip-resistance), acceptable and unacceptable materials are not easy to categorize....
-
Size and Clearances [4.21.2]
The 36 by 36 inch dimension, measured to the interior finish, keeps front and side grab bars within reach from the seat....
-
3 - Best practices for pre - construction meetings
Unusual or particularly tight tolerances can be discussed, questions asked, construction techniques suggested, measurement methods outlined, and how compliance will be checked can all be...
-
11B-604.9.6 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 _|Operation|_ and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
BACKGROUND
The parties (“Parties”) to this Settlement Agreement (“Agreement”) are the United States of America (“United States”) and Franciscan St. James Health (“St....
-
I.
Cinemark filed suit against the United States in the United States District Court for the Northern District of Texas on January 28, 1999, alleging that the Department's interpretation of...
-
704.11.1 Parapet construction
Where the roof slopes toward a parapet at a slope greater than two units vertical in 12 units horizontal (16.7-percent slope), the parapet shall extend to the same height as any portion...
-
Other Resources
Adapted Fire Extinguisher A trigger mechanism eliminates the pull pin from the unit and instead has a spring device that locks the trigger in place....