Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
Search Results "Unit of Measurement"
-
306.1 General
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
4.13.5 CLEAR WIDTH
Doorways shall have a minimum clear opening of 32 in (815 mm) with the door open 90 degrees, measured between the face of the door and the stop (see Fig. 24(a), (b), (c), and (d))....
-
§ 38.159(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75 mm), and the transition from roadway...
-
11B-604.9.6 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
604.9.6 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
407.2.2.2 Visible Signals
The visible signal elements shall be 2 1/2 inches (64 mm) minimum measured along the vertical centerline of the element....
-
604.9.6 Dispensers
Toilet paper dispensers shall comply with 309.4 and shall be 7 inches (180 mm) minimum and 9 inches (230 mm) maximum in front of the water closet measured to the centerline of the dispenser...
-
406.8 Detectable Warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured...
-
502.6 Identification
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. Advisory 502.6 Identification....
-
221.9 Stadium Style Movie Theaters
criteria: (i) It is located within the rear 60% of the seats provided in an auditorium; or (ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured...
-
11B-224.8.2 More than 50-bed facilities
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units that are subject...
-
11B-224.8.2 More than 50-bed facilities
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units that are subject...
-
C. Needs of Individuals with Chemical and Electrical Sensitivities
The advisory committee discussed issues related to the indoor environmental quality of emergency transportable housing units, but the committee concluded that it did not have the expertise...
-
End of Document
McSWAIN United States Attorney GREGORY B....
-
224.6 Housing at a Place of Education
Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping rooms...
-
Updates and Other Pocket Guides
For ADA survey and compliance tools that will simplify your field measurement process and plan reviews, the Corada Shop has a growing collection of templates and tools that you can download...
-
Islands: ADA Standard Section 406.7
Section 406.7 covers the current ADA Standards for islands.
-
11B-707.4 Privacy
., a covered entity does not have to take measures that would result in a fundamental alteration of its program or would cause undue burdens, provide adequate protection to operators of...
-
11B-707.4 Privacy
., a covered entity does not have to take measures that would result in a fundamental alteration of its program or would cause undue burdens, provide adequate protection to operators of...
-
ETA Public Telephone Summary Chart and Survey Instructions
Accessible unit may be installed as a single unit in proximity (either visible or with signage) to the bank. [4.1.3(17)(a)] d. 1 per bank, when 2 or more banks are provided....
-
Definitions of residential facilities and transient lodging. (Section-by-Section Analysis)
The 2010 Standards add a definition of ‘‘residential dwelling unit'' and modify the current definition of ‘‘transient lodging.''...
-
1.9.1.1.3
1.9.1.1.3 All publicly funded buildings used for congregate residences or for one- or two-family dwelling unit purposes shall conform to the provisions applicable to living accommodations...