occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground tunnels, shall...
Search Results "Shall"
-
11B-203.6 Single occupant structures
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
-
11B-223.2.3 On-call rooms
Where physician or staff on-call sleeping rooms are provided, at least 10 percent, but no fewer than one, of the on-call rooms shall provide mobility features complying with Sections 11B...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-203.6 Single occupant structures
occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground tunnels, shall...
-
11B-223.2.3 On-call rooms
Where physician or staff on-call sleeping rooms are provided, at least 10 percent, but no fewer than one, of the on-call rooms shall provide mobility features complying with Sections 11B...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
-
11B-502.2 Vehicle spaces
Car and van parking spaces shall be 216 inches (5486 mm) long minimum....
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall...
-
11B-605.4 Flush controls
Flush controls shall be hand operated or automatic....
-
11B-1007.2 Accessible routes
Accessible routes serving holes on miniature golf courses shall comply with Division 4....
-
11B-1007.2 Accessible routes
Accessible routes serving holes on miniature golf courses shall comply with Division 4....
-
11B-903.4 Back support
The bench shall provide for back support or shall be affixed to a wall along its long dimension....
-
11B-903.4 Back support
The bench shall provide for back support or shall be affixed to a wall along its long dimension....
-
1134A.5 Bathtubs
The controls shall be on the wall at the foot of the bathtub. The edge of the clear floor space shall be flush with the control wall surface....
-
604.8.1.5 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
709.5 Openings
Openings in a smoke barrier shall be protected in accordance with Section 714. Opening protectives shall have a minimum fire-protection rating of 20 minutes....
-
11B-411.2.1.2.5 Audio output
Audio output shall be recorded or digitized human speech, and shall be delivered through a loudspeaker....
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
-
1134A.7, Item 2
The grab bar reinforcement shall be a minimum of 6 inches (152.4 mm) nominal in height. The backing shall be a minimum of 40 inches (1016 mm) in length....