Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
Search Results "Shall"
-
11B-609.2.2 Non-circular cross section
-
11B-203.3 Raised areas
primarily for purposes of security, life safety, or fire safety, including but not limited to, observation or lookout galleries, prison guard towers, fire towers, or life guard stands shall...
-
11B-227.2.1 Altered check-out aisles
Where check-out aisles are altered, at least one of each check-out aisle serving each function shall comply with Section 11B-904.3 until the number of check-out aisles complies with Section...
-
11B-411.2.1.4.1 Hall call console additional buttons
Hall call console buttons provided in addition to the accessibility function button and keypad buttons shall comply with Section 11B-411.2.1.4.1....
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat. ...
-
206.4 Entrances
Entrances shall be provided in accordance with 206.4. Entrance doors, doorways, and gates shall comply with 404 and shall be on an accessible route complying with 402....
-
F206.4 Entrances
Entrances shall be provided in accordance with F206.4. Entrance doors, doorways, and gates shall comply with 404 and shall be on an accessible route complying with 402....
-
206.4 Entrances
Entrances shall be provided in accordance with 206.4. Entrance doors, doorways, and gates shall comply with 404 and shall be on an accessible route complying with 402....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-411.2.1.2.3 Accessibility function button
The accessibility function button shall be identified by the International Symbol of Accessibility and a raised indication....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
Height: ADA Standard Section 704.4.1
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
-
Clear Floor Space: ADA Standard Section 1004.1
Exercise machines and equipment shall have a clear floor space complying with 305 positioned for transfer or for use by an individual seated in a wheelchair....
-
Within a Site: ADA Standard Section 206.2.2
Section 206.2.2 covers the scoping requirements for accessible routes within a site in the most current ADA Standards.
-
Dispersion: ADA Standard Section 235.2.1
Section 235.2.1 covers scoping requirements in the current ADA Standards for dispersion of boat slips.
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-810.6 Rail station signs
Rail station signs shall comply with Section 11B-810.6....
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
11B-209.4 Valet parking
Parking facilities that provide valet parking services shall provide at least one passenger drop-off and loading zone complying with Section 11B-503....