Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
Search Results "Minimum Dimension"
-
11B-703.8.9 Height above floor
-
11B-410.7 Landing size
The minimum size of landings at platform lifts shall be 60 inches by 60 inches (1524 mm by 1524 mm)....
-
11B-707.7.2 Characters
Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
11B-804.2.2 U-Shaped
U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524 mm) minimum...
-
11B-810.3 Bus shelters
Bus shelters shall provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter....
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
707.7.2 Characters
Characters shall be 3/16 inch (4.8 mm) high minimum based on the uppercase letter "I"....
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
503.5 Vertical Clearance
and a vehicular route from an entrance to the passenger loading zone, and from the passenger loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2895 mm) minimum...
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
Shower Compartments
• Roll-in showers are 30 inches wide minimum by 60 inches long minimum....
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38, 4.23.9, 4.34.5.3(3)]...
-
11B-804.3.2 Height
Exception: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted....
-
1008.2 Accessible Routes
Where accessible routes serve ground level play components, the vertical clearance shall be 80 inches high (2030 mm) minimum....
-
STEP 3 Compare which is greater
The greater number is considered to be the minimum number of ground level play components required to be on an accessible route....
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. [ECTCR UFAS 4.25.3, Fig. 38]...
-
e-vi
Are signs mounted on both sides of the elevator hoist way door opening (for each elevator and at each floor) that designate the floor with 2-inch minimum-height raised letters and Braille...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
9.5.2(2)(e)
(e) at least one route connecting elements (a), (b), (c) and (d) which a person with mobility impairments can use including minimum clear width of 36 in (915 mm), passing space complying...
-
R406.2 Unobstructed Forward Reach
Where a forward reach is unobstructed, the high forward reach shall be 1220 mm (4.0 ft) maximum and the low forward reach shall be 380 mm (1.25 ft) minimum above the finish surface....
-
1016.8.2 Width
Resting intervals that are provided adjacent to an outdoor recreation access route are required to be 36 inches wide minimum....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...