Where guest rooms are altered or added, the requirements of 224 shall apply only to the guest rooms being altered or added until the number of guest rooms complies with the minimum number...
Search Results "Minimum Dimension"
-
224.1.1 Alterations
-
604.3.2 Overlap
[ECTCR UFAS 4.16.2, Fig. 28, 4.34.5.2(1), Fig. 47(a)] EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum...
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
Recommendations The Committee recommends standing supports located on one side of the platform, integrated into the platform and stretching the full length of the platform (40-inch minimum...
-
R208.2 Where Not Required
surfaces are not required at cut-through pedestrian refuge islands that are less than 1.8 meters (6.0 ft) in length because detectable warning surfaces must extend 610 millimeters (2.0 ft) minimum...
-
R302.3 Continuous Width
Except as provided in R302.3.1, the continuous clear width of pedestrian access routes shall be 1.2 m (4.0 ft) minimum, exclusive of the width of the curb....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
Maneuvering Space at Doors
Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard....
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
T201 General
Chapter 2 to the extent required by DOT’s implementing regulations for ADA-covered transportation vehicles, which, when revised, are required to use the 2016 Non-Rail Vehicle Guidelines as minimum...
-
3.3.12 180-Degree Turn around a Barrier
If the barrier is less than 1220 mm (48 in.) wide, the standard calls for a minimum passage width of 1065 mm (42 in.) and a minimum turn-around space depth of 1220 mm (48 in.)....
-
Beach Access Routes
The proposed rule would have required the clear width of beach access routes to be 36 inches minimum....
-
§ 38.23(b)(13) Handrails
Handrails shall have a usable component at least 8 inches long with the lowest portion a minimum 30 inches above the platform and the highest portion a maximum 38 inches above the platform...
-
§ 38.95(b)(13) Handrails
Handrails shall have a usable component at least 8 inches long with the lowest portion a minimum 30 inches above the platform and the highest portion a maximum 38 inches above the platform...
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
§ 38.125(b)(13) Handrails
Handrails shall have a usable component at least 8 inches long with the lowest portion a minimum 30 inches above the platform and the highest portion a maximum 38 inches above the platform...
-
§ 38.83(b)(13) Handrails
Handrails shall have a usable component at least 8 inches long with the lowest portion a minimum 30 inches above the platform and the highest portion a maximum 38 inches above the platform...
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
- Viking E-1600-02A-EWP Emergency Phones with Built-in Auto Dialer and Digital Announcer with Weather Protection
- Viking E-1600-55A Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Excel Dryer, Inc. LEXAN® Series Hand Dryers
- Viking E-1600-20A Emergency Phones with Built-in Auto Dialer and Digital Announcer
- Viking E-1600-03B Emergency Phones with Built-in Auto Dialer and Digital Announcer