comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum...
Search Results "Minimum Dimension"
-
604.8.1.2 Doors
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches (1524...
-
Table Surface Height
Some commenters also recommended a higher minimum height of 29 inches instead of 28 inches to allow a more comfortable knee clearance. Response....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (455 mm) minimum by 18 inches (455 mm) minimum, centered on the tactile characters, is provided...
-
Transfer Supports Location and Configuration M301.3 and M302.3
Transfer Supports Location and Configuration M301.3 and M302.3 Location of the transfer supports shall be a minimum of 6 inches to a maximum of 19 inches from the top of the transfer...
-
Backrests
Back supports should be a minimum of 18 inches from the seat surface to the top of the support....
-
14.4 Q. If a covered multifamily dwelling has a below grade common use parking garage, is there a requirement for a vertical clearance to allow vans to park?
In response to comments from the public that the Guidelines for parking specify minimum vertical clearance for garage parking, the Department responded: No national accessibility standards...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
604.8.1.2 Doors
comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42 inches (1065 mm) minimum...
-
Sec. 12150. Interim accessibility requirements. [Section 230]
12147 of this title, except that, if such final regulations have not been issued one year after the Architectural and Transportation Barriers Compliance Board has issued the supplemental minimum...
-
12186(d)(1) Facilities
12183 of this title, except that, if such final regulations have not been issued one year after the Architectural and Transportation Barriers Compliance Board has issued the supplemental minimum...
-
12165(a) Stations
(e) of this title, except that, if such final regulations have not been issued one year after the Architectural and Transportation Barriers Compliance Board has issued the supplemental minimum...
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
407.12.2.1 Unobstructed Side Reach (Section-by-Section Analysis)
This section proposes that, where the operable part is located 10 inches or less behind the vertical reference plane, the operable part must be 48 inches high maximum and 15 inches high minimum...
-
R214 On-Street Parking Spaces (Section-by-Section Analysis)
R214 On-Street Parking Spaces (Section-by-Section Analysis) Where on-street parking is provided on the block perimeter and the parking is marked or metered, a minimum number of parking...
-
4.1.2(5)(a)
Total Parking in Lot Required Minimum Number of Accessible Spaces 1 to 25 1 26 to 50 2 51 to 75 3 76 to 100...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
The clear width of ramp runs would be required to be 36 inches minimum....
-
11B-233.3.3 Additions
units, the requirements of Section 11B-233.3.1 shall apply only to the residential dwelling units that are added until the total number of residential dwelling units complies with the minimum...
-
11B-704.4.1 Height
When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....