607.5 Controls
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
Submerged Depth: ADA Standard Section 1009.3.2
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
11B-806.3.2 Notification devices
Telephones shall be served by an electrical outlet complying with Section 11B-309 located within 48 inches (1219 mm) of the telephone to facilitate the use of a TTY....
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-703.6.1 Pictogram field
Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
5.4 Recruitment
(See Locating Qualified Individuals with Disabilities below)....
-
§27.71(h)(3)(ii)
(ii) A service animal training organization, the airport, and the carriers in the terminal in which the relief area will be located agree that a relief area would be better placed outside...
-
Accessible Parking Spaces for Cars
Accessible parking spaces for cars have at least a 60-inch-wide access aisle located adjacent to the designated parking space....
- ClickAndGo Navigation Wayfinding Technology
-
Issue 8: Rest-in-WALK (quiet time ok)
Issue 8: Rest-in-WALK (quiet time ok) In some locations, the pedestrian signals ‘rest-in-WALK’ and it may not be desirable to have the WALK indication repeat constantly during the long...
-
5.3.2 Transfer Sides Recommendations for M301
5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short side and...
- Takeform Fusion Signage Evacuation Map Type D
- NuStep T5XR Recumbent Cross Trainer
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
11B-206.2.8 Employee work areas
Common use circulation paths located within employee work areas that are less than 1000 square feet (93 m2) and defined by permanently installed partitions, counters, casework, or furnishings...
-
Toilet Paper Dispensers
measured to the centerline of the dispenser.The paper outlet of the dispenser must be located 15 inches minimum and 48 inches maximum above the finish floor....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
- KirbyBuilt Providence Walk-Thru Picnic Table
- Just Manufacturing Deck Mounted Gooseneck Two Handle Mixing Bar Sink Faucet
- Alertus Text-To-Speech Self Amplified Speaker