Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
Search Results "Space Allowance"
Commonly Searched Documents
-
11B-610.4 Structural strength
-
11B-604.5.2 Rear wall
The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm) minimum due to the...
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an...
-
11B-604.7 Dispensers and disposal units
Combination accessory units are not permitted to encroach into the space required by Section 11B-609.3. [2010 ADA Standards] 604.7 Dispensers....
- Otis Gen2 Elevator
-
Structural Strength: ADA Standard Section 609.8
Section 609.8 covers the current ADA Standards for the structural strength of grab bars.
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
ACCESSIBILITY
[DSA-AC] Accessibility is the combination of various elements in a building, facility, site, or area, or portion thereof which allows access, circulation and the full use of the building...
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The technical requirements address clear floor space, height, faucets, and exposed pipes and surfaces....
-
4.3.5.2 180-degree turn
The 1525 mm (60 in.) turning space would be used instead....
-
1127B.1
In existing buildings, this section shall not apply in those conditions where, due to legal or physical constraints, the site of the project would not allow compliance with these regulations...
- Boost Your Business - Chapter 7 - Halls and Fountains
-
PLATFORM (WHEELCHAIR) LIFT
platform or support that serves two landings of a building or structure and is designed to carry a passenger or passengers and/or luggage or other material a vertical distance as may be allowed...
-
Visual Characters
This section applies to those pictograms, where provided, that are used to label permanent interior rooms and spaces....
-
Mounting Location and Height [4.30.6]
Space must be available for a close approach outside the swing of doors. It is important that fixed elements (e.g., drinking fountains) and furnishings not obstruct the approach....
-
Edge Protection
This design allows a person using a wheelchair or other mobility device to pull into a clear space and move beyond the face of the railing to view the water in different directions....
-
Scoping [4.1.3(12)]
Scoping [4.1.3(12)] ADAAG covers fixed or built-in storage facilities in public or common use spaces and requires access to at least one of "each type."...
-
4.17.3 SIZE AND ARRANGEMENT
Arrangements shown for stalls may be reversed to allow either a left- or right-hand approach....
-
Alarms: ADA Standard Section 807.3.1
EXCEPTION: Visible alarms shall not be required where inmates or detainees are not allowed independent means of egress....
-
Seat Height: ADA Standard Section 1009.2.4
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-703.8.6 Stroke width
The uppercase letter “I” shall be used to determine the allowable stroke width of all low resolution VMS characters of a font....
-
11B-604.5.2 Rear wall
The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm) minimum due to the...
-
11B-604.5.2 Rear wall
Exceptions: The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (914 mm...