If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
Search Results "Side-Opening Door"
Commonly Searched Documents
-
D5
-
M5
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
D5. Raised Threshold
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
§ 38.153(d)
(d) The overhead clearance between the top of the lift door opening and the sill shall be the maximum practicable but not less than 65 inches (1651 mm)....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
[2010 ADAS] 105.2.1 ANSI/BHMA
ANSI/BHMA A156.10-1999 applies to power operated doors for pedestrian use which open automatically when approached by pedestrians....
- ELKAY Filtered EZH2O® Bottle Filling Station with Integral Soft Sides® Fountain LZWS-EDFP217K
- Carr Corporation Specimen Pass Through SPT24
-
Signage
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
GUARD [DSA-AC, HCD 1, HCD 2 & HCD 1-AC] OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Where a door is provided the symbol shall be mounted within 1 inch (25 mm) of the vertical centerline of the door....
-
608.2.2.1 Clearance
A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
Best Practice Recommendations for Layout Planning
When possible, include both “horizontal” (side to side) and “vertical” (front to back) aisles to improve access and flow....
-
1008.1.9.7, Item 5
A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
- Panda US.51 All Aluminum ULTRA Folding Door System
-
§ 38.31(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread or lift platform....
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....