Car Controls [4.10.12]
Control panels must be located so that no floor button is higher than 54 inches for a side reach and 48 inches for a front approach....
-
11B-504.8 Floor identification
They must be tactile, and located at the latch side of the door inside the stairway as prescribed by CBC Section 11B-703.4....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
Current Accessibility Guidelines That Apply to the Forest Service
Crew quarters Visitor centers Entrance stations Parking lots Building components such as: Restrooms with and without water Work stations Doors...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
§ 38.73(a)(1)
(1) All passenger doorways on vehicle sides shall have minimum clear openings of 32 inches when open....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Temporary Measures
For example, if the only entrance door at a polling place is 29 inches wide, then propping the door open or providing a doorbell for a poll worker to open the door will still not allow a...
- Access Board: Tactile Sign Clear Floor Space
-
Turnstiles and Security Gates at Entrances
It may be readily achievable to add an accessible door handle to the outside of the exit door, install a sign that designates this door as the accessible entrance, and permit people with...
-
H1
[ADA Standards § 4.30.6] Yes No If No, install a sign with raised characters and Braille on the wall adjacent to the latch side of the door and centered 60 inches above the...
-
1010.2.13.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....