Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
Search Results "Clear Tread Width"
Commonly Searched Documents
-
306.3.3 Minimum Required Depth
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
4.34.5.5(1) Size and clearances
Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
11B-1008.2.3 Water play components
Exceptions: Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302,...
- Don-Jo Mfg., Inc. Vertical Rod Protector 85
- Don-Jo Mfg., Inc. Vertical Rod Protector 81
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
This smooth surface must extend the full width of the door or gate....
-
1.1.13 Flatness of ramp running slope
For ramps over 5 ft (1525 mm) in width between handrails measure along an additional line for each additional 36 in. (915 mm) of width or fraction thereof beyond 5 ft (1525 mm)....
-
1007.6.1 Size
Such wheelchair spaces shall not reduce the required means of egress width....
-
Revolving Doors or Turnstiles
automated revolving doors, if large enough, may be usable by people with disabilities, certain questions remain about the appropriate maximum speed, minimum diameter, compartment size, width...
-
Ambulatory Accessible Compartment
The width of ambulatory compartments is specified to ensure that the grab bars required on both sides are simultaneously within reach....
-
Sloped Entries
Sloped Entries Sloped entries must comply with ADAAG accessible route provisions (36 inch minimum width, maximum 1:12 or 8.33% slope), except that the surface does not need to be slip...
-
Ramp
The ramp had a constant width of 30 inches and was 1 inch thick. The minimum length was 8 inches and the maximum length was 11 inches....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
Platform Edges
Where this breakaway material is installed at a platform edge, the width of the detectable warning surface can begin at the edge of the breakaway material rather than at the edge of the...
-
36 Inch Wide Stalls
A 36-inch width (absolute) allows the parallel grab bars to be used simultaneously when changing from a standing position to a seated position and vice versa....
-
1009.6.3 Size
Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
§ 38.23(d)(4) Orientation
wheelchair or mobility aid facing forward, or rearward with a padded barrier, extending from a height of 38 inches from the vehicle floor to a height of 56 inches from the vehicle floor with a width...
-
1009.6.3 Size
Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity....
-
Re: Lavatories Adjacent to Partitions
adjacent to sidewall or partition to be a minimum of 18" to the centerline of the fixture without reference to dispensers or similar elements (as commented previously). 11B-606.2 requires clear...