Accessible spaces, including van spaces, must be located so that they provide the same level of protection and security as other spaces in the garage....
Search Results "Signage Location"
Commonly Searched Documents
-
Multi-Level Parking Garage Not Serving a Particular Facility
-
1007.9 Signage
1007.9 Signage. Signage indicating special accessibility provisions shall be provided as shown: 1....
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
Viewing areas often provide more than one distinct viewing location....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
Control End Wall: ADA Standard Section 607.4.2.2
Section 607.4.2.2 covers the current ADA Standards for grab bars on the control end of bathtubs without permanent seats.
-
Head End Wall: ADA Standard Section 607.4.2.3
Section 607.4.2.3 covers the current ADA Standards for grab bars on the head end wall of bathtubs without permanent seats.
-
Control End Wall: ADA Standard Section 607.4.1.2
Section 607.4.1.2 covers the current ADA Standards for grab bars on the control end of bathtubs with permanent seats.
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub.
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub.
-
11B-502.6 Identification
. ◼ Exception: Signs located within a circulation path shall be a minimum of 80 inches (2032 mm) above the finish floor or ground surface measured to the bottom of the sign....
-
A6. ISA Signage
A6. Does each accessible parking space have a sign with the symbol of accessibility that is visible when a vehicle is parked in the space? [ADA Stds 4.6.4] Yes _____ No _____
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish...
-
Information and Directional Signs
Information and directional signs are addressed by 216.3. These types of signs are not required to be tactile but are subject to requirements for visual legibility and contrast....
-
4.6.2 Location
Accessible parking spaces serving a particular building shall be located on the shortest accessible route of travel from adjacent parking to an accessible entrance....
-
206.3 Location
Accessible routes shall coincide with or be located in the same area as general circulation paths....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: 1....
-
§ 38.113(e) Signage
(e) Signage....
-
11B-216.11 Check-out aisles
Where check-out aisles are identified by numbers, letters, or functions, signs identifying check-out aisles complying with Section 11B-904.3 shall be located in the same location as the...
-
4.6.2 LOCATION
Parking spaces for disabled people and accessible passenger loading zones that serve a particular building shall be the spaces or zones located closest to the nearest accessible entrance...
-
B8
B8. Are the accessible parking spaces serving the shelter on the shortest accessible route to the accessible entrance? [ADA Standards § 4.6.2] Yes No
-
A8. Accessible Route
A8. Are the accessible parking spaces serving the voting area on the shortest accessible route to the accessible entrance? [ADA Stds 4.6.2] Yes _____ No _____