Section 223.2.1 covers scoping requirements in the current ADA Standards for facilities not specializing in treating conditions that affect mobility.
Search Results "Patient in Supine Position"
Commonly Searched Documents
-
Facilities Not Specializing in Treating Conditions That Affect Mobility: ADA Standard Section 223.2.1
- Guldmann Basic High Sling
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5....
-
11B-407.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum.
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface.
-
M305.3.2 Vertical Position
Where the support is vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided....
-
Facilities Specializing in Treating Conditions That Affect Mobility: ADA Standard Section 223.2.2
Section 223.2.2 covers scoping requirements in the current ADA Standards for facilities specializing in treating conditions that affect mobility.
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
M304.2.1 Slip Resistant
The surface on which the patient stands shall be slip resistant....
-
M304.2 Standing Surface
The surface on which the patient stands shall be slip resistant....
-
M304.2 Standing Surface
Equipment surfaces on which patients stand must comply with M304.2...
- Hill-Rom Sabina® II Mobile Lift
-
Patient Toilet Rooms [6.4]
Patient Toilet Rooms [6.4] ADAAG specifications are based on the independent use of toilet and bathing facilities and do not address alternate designs for assisted use....
-
vii. Ancillary equipment
Ancillary equipment includes items such as positioning straps or cushions; protective padding; adjustable, padded leg supports for gynecological examinations; and additional supports, rails...
-
1. Standing Supports
to assist the patient in standing....
-
M302.2.1 Adjustability
A low transfer position at a height of 17 inches (430 mm) minimum and 19 inches (485 mm) maximum; B. A high transfer position at 25 inches (635 mm); and C....
-
Patient Bedrooms [6.3]
[See subsections ...]
- Hoyer Ascend Stand-Up Lift
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.
-
M305.3 Standing Supports (Section-by-Section Analysis)
M305.3 provides the technical requirements for standing supports which are required on diagnostic equipment covered by M304. This provision has been reorganized in the final rule...
-
M304.3 Standing Supports
Standing supports shall be provided on each side of the standing surface and shall comply with M305.3.
-
M305.3 Standing Supports
Standing supports shall provide continuous support throughout use of the diagnostic equipment and shall comply with M305.3.