Where the support is horizontal, the top of the gripping surface shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface. The gripping surface...
Search Results "Patient in Supine Position"
Commonly Searched Documents
-
M305.3.1 Horizontal Position
-
5.2.2.2 Transfer Surface Depth Recommendation for M302
5.2.2.2 Transfer Surface Depth Recommendation for M302 The Committee recommends a minimum depth requirement of 17 inches for equipment used by patients in seated positions....
-
5.2.2.1 Transfer Surface Width Recommendations for M302
Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily used by patients...
-
M303 Diagnostic Equipment Used by Patients in a Wheelchair (Section-by-Section Analysis)
M303 in the final rule establishes the technical requirements for diagnostic equipment used by patients seated in a wheelchair, such as weight scales with wheelchair spaces and mammography...
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. ...
-
Hill-Rom Viking® M Patient Lift
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Shooting Facilities with Firing Positions: ADA Standard Section 1010
[See subsections ...]
-
5.9.1 Standing Supports In Reference To Mammography Equipment
To be useful, positioning supports must be shaped for grasping, positioned within reach range of all users, and be 12 inches long minimum when located on the moving C-arm or 18 inches long...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2....
-
Using Patient Lifts
Using Patient Lifts Medical providers may need a lift in order to transfer some patients safely onto an exam table....
-
11B-1010 Shooting facilities with firing positions
[See subsections ...]
-
11B-243 Shooting facilities with firing positions
[See subsections ...]
-
11B-703.3.2 Position
Braille shall be positioned below the corresponding text in a horizontal format, flush left or centered. If text is multi-lined, Braille shall be placed below the entire text....
- Figure 703.3.2 Position of Braille – Drawing from the U.S. Access Board
-
M304.2.2 Standing Supports (Section-by-Section Analysis)
The MDE NPRM proposed requiring standing supports on each side of the standing surface of diagnostic equipment used by patients in the standing position, and compliance with the technical...
-
11B-411.4.8 Car position indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
3.1 Getting Weighed
An accessible scale benefits more than just patients who use wheelchairs....
- Hill-Rom Viking® M Patient Lift
- Hill-Rom Golvo® 8000 / 8008 Patient Lift
-
5.2.2 Transfer Surface Size Recommendations for M302
5.2.2 Transfer Surface Size Recommendations for M302 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer...
- Hoyer Advance-H Patient Lift