Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
Search Results "Dimension"
Commonly Searched Documents
-
1017.6 Openings
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
Lift
Consequently, a common wheelchair is one that fits these size and weight dimensions....
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
- International Disability and Development Consortium (IDDC)
-
Baby Changing Tables
The specified dimensions of toilet compartments provide the minimum amount of space necessary for wheelchair maneuvering into the compartment, positioning at the fixture, and exit from the...
-
5.3.2 Transfer Sides Recommendations for M301
Patients who use mobility devices would have the choice to approach parallel to the deep dimension of the transfer surface, parallel to the wide dimension of the transfer surface, or at...
-
Notes:
Given the differing shapes of mammography devices, defining the dimensions in relationship to each other with a static measurement point for the breast platform assures accessibility despite...
-
Gratings [4.5.4]
ADAAG requires a maximum opening dimension of ½ inch in one direction and that elongated openings be placed so that the long dimension is perpendicular to the dominant direction of travel...
-
Construction Specification Institute
For longitudinal lines, measurements were to be taken in minimum 5 - foot lengths running parallel to the long dimension, with one measurement line per 3 feet of width and within 2 feet...
-
M301.3 Transfer Supports
* Other Transfer Support Dimensions: (*not included in the Proposed Rule) • Sub-committee Recommendation: Length - At least 15 inches (300 mm) in length and located on the length...
-
4.5.4 Gratings
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
4.5.4 GRATINGS
If gratings have elongated openings, then they shall be placed so that the long dimension is perpendicular to the dominant direction of travel (see Fig. 8(h))....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Figure 302.3 Elongated Openings in Floor or Ground Surfaces...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
Bus boarding and alighting areas
Bus boarding and alighting areas must be in compliance with the ADA-ABA Guidelines (Section 810.2), which address surfaces (sturdy), dimensions (96" long x 60" wide); connection to sidewalks...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
F104.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
11B-104.2 Calculation of percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
104.2 Calculation of Percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
302.3 Openings
Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. Figure 302.3 Elongated Openings in Floor or Ground Surfaces ...