Door reopening devices shall remain effective for 20 seconds minimum....
Search Results "Automatic Door"
-
11B-407.3.3.3 Duration
-
Duration: ADA Standard Section 407.3.3.3
Section 407.3.3.3 covers the current ADA Standards for the duration of an elevators reopening device.
-
3.3.16 Door Use
3.3.16 Door Use A total of 144 WhMD users completed door use tasks for at least one of the doors....
- DORMA ED400 Swing Door Operator
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
Contact: ADA Standard Section 407.3.3.2
Section 407.3.3.2 covers the current ADA Standards for the contact requirements of an elevators reopening device.
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
-
A4.13.11(2) Sliding or folding doors
(2) Sliding or folding doors: Force applied parallel to the door at the door pull or latch....
- BEA Inc. PBDGP Series Vestibule Push Plate (Push to Open)
-
11B-220.1 Automatic teller machines and fare machines
SECTION TITLE NOTES 11B-220.1 Automatic teller machines and fare machines. Ā ...
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
11B-206.5.1 Entrances
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
-
707 Automatic Teller Machines and Fare Machines
Section 707 provides specifications for Automatic Teller Machines (ATMs) and fare machines....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
Entry Doors
Entry Doors Under the ADA Standards for Accessible Design, an accessible doorway must have a minimum clear opening width of 32 inches when the door is opened to 90 degrees....
- Horton ProSlideĀ® Series 2003 Belt Drive System
-
Privacy: ADA Standard Section 707.4
Automatic teller machines shall provide the opportunity for the same degree of privacy of input and output available to all individuals. Advisory 707.4 Privacy....
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
- Besam Hurricane Resistant Automatic Sliding Door 1012494 SL500 SA Clean Room BP Narrow Stile Rev 2.0
- Besam Hurricane Resistant Automatic Sliding Door 1012493 SL500 SA Clean Room SS Narrow Stile Rev 2.0
- BEA Inc. Jamb Style Door Access PTE (Push To Exit)