Stroke thickness of the uppercase letter “I” shall be 15 percent maximum of the height of the character....
Search Results "Seat Height"
-
11B-703.2.6 Stroke thickness
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
ASME
This document does not permit the use of inclined stairway chairlifts which do not provide platforms because such lifts require the user to transfer to a seat....
-
11B-1002.6 Transfer devices for use with amusement rides
Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems....
-
Wheelchair Spaces in Tiered Boxes
In certain performing arts facilities, seating may be provided in tiered boxes for spatial and acoustical purposes. Often, steps are located on the route to these boxes....
-
1002.6 Transfer Devices for Use with Amusement Rides
Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems....
-
1115B.4.4.8, Item 1
A folding seat mounted 18 inches (457 mm) above the floor, and with a minimum space of 1 inch (25 mm) and maximum space of 1 1/2 inches (38 mm) allowed between the edge of the seat and any...
-
11B-1002.6 Transfer devices for use with amusement rides
Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems....
-
11B-1002.6 Transfer devices for use with amusement rides
Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems....
-
1002.6 Transfer Devices for Use with Amusement Rides
Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems....
-
1002.6 Transfer Devices for Use with Amusement Rides
Examples of devices that may provide for transfers include, but are not limited to, transfer systems, lifts, mechanized seats, and custom designed systems....
-
1.12 Future Construction Theaters
Theaters" or "Designed Theaters" for which permits for construction were issued on or after the Effective Date of this Consent Order and which have been built in conformance with any of the seating...
-
6. Grab Bars
Is there a horizontal grab bar at the head of the tub that is at least 12" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat - see Figure 34 on page 25?...
-
11B-809.8 Doors
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than 1/2 inch (12.7 mm) of change in height between floor surfaces....
-
11B-411.2.1.2.1 Keypads
The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
Clear Floor or Ground Space: ADA Standard Section 407.2.1.3
Section 407.2.1.3 covers the current ADA Standards for the clear floor or ground space at elevator call controls.
-
11B-411.2.1.2.1 Keypads
The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
- SLOPE Waste Receptacles
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
4.34.6.5(2)
(2) Rough-in plumbing shall be located to accept connections of supply and drain pipes for sinks mounted at the height of 28 in (710 mm)....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
703.6.1 Pictogram Field
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field....
-
206.2.6 Performance Areas
Where a circulation path directly connects a performance area to an assembly seating area, an accessible route shall directly connect the assembly seating area with the performance area....