TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES TOTAL NUMBER OF GUEST ROOMS PROVIDED MINIMUM NUMBER OF REQUIRED ROOMS WITHOUT ROLL-IN...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-224.2.2 More than fifty guest room facilities
-
Audible Hall Signals
The Board has added a requirement in the final rule that hall signal verbal annunciators have a frequency of 300 Hz minimum and 3,000 Hz maximum....
-
Statutory Background
covered by the Americans with Disabilities Act (ADA) of 1990.1 The Board holds a similar responsibility under the Architectural Barriers Act (ABA) of 1968.2 The Board's guidelines provide a minimum...
-
M305.3.1 Length (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed a gripping surface length of four inches minimum for horizontal standing supports. No public comments were submitted on this requirement....
-
Issue 14: How can improved lighting and zero net energy goals by achieved while improving health care?
And that’s the minimum. So when they do their energy analysis, they can’t go below those minimums, which are not necessarily as low as some suggestions around here....
-
232.2.1 Cells with Mobility Features
New construction of jails, prisons, and other detention and correctional facilities by public entities shall provide accessible mobility features complying with section 807.2 for a minimum...
-
11B-604.3.2 Overlap
Application Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.3.2: Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum...
-
11B-406.5.3 Landings
The landing clear length shall be 48 inches (1219 mm) minimum....
-
11B-802.1.3 Depth
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1219 mm) deep minimum....
-
Fact Sheet: Highlights of the Final Rule to Amend the Department of Justice's Regulation Implementing Title III of the ADA
The ADA requires the Department to publish ADA design standards that are consistent with the minimum guidelines published by the U.S....
-
Trash and Recycling Receptacles [1011.2 and 1011.3]
At trash and recycling containers, a minimum of 36 by 48 inches of clear ground space positioned for a forward approach to the receptacle opening, or a minimum of 30 by 60 inches of...
-
Sec.36.601 Definitions
Certification of equivalency means a final certification that a code meets or exceeds the minimum requirements of title III of the Act for accessibility and usability of facilities covered...
-
1017.3 Clear Tread Width
This section requires the clear tread width of trails to be 36 inches minimum....
-
§ 38.77(c)
allow a route at least 32 inches wide so that at least two wheelchair or mobility aid users can enter the vehicle and position the wheelchairs or mobility aids in areas, each having a minimum...
-
11B-802.1.3 Depth
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1219 mm) deep minimum....
-
11B-802.1.3 Depth
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1219 mm) deep minimum....
-
Measures and Procedures
The space for the legs and feet has a fixed dimension of 14.5” deep by 22.5” wide (36.8x57.2cm)....
-
Utilities at Recreation Sites
Place elongated openings more than a quarter of an inch wide with the long dimension perpendicular to the primary direction of travel....
- American Standard Times Square Deck- Mount Bathtub Faucet with Personal Shower
- Elkay Cane Apron LKAPREZL for use with EZ Bi-Level Drinking Fountains
-
605.2 Height and Depth
Urinals shall be 13½ inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. Figure 605.2 Height and Depth of Urinals...
-
12204(c)(3) Other sites
guidelines described in paragraph (1) shall establish procedures equivalent to those established by 4.1.7(1) (b) and (c) of the Uniform Federal Accessibility Standards, and shall require, at a minimum...
-
§1607.14 Technical standards for validity studies.
The following minimum standards, as applicable, should be met in conducting a validity study....