Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302 _|Floor or Ground...
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
-
11B-1008.2.3 Water play components
-
11B-809.2.2 Turning space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-809.2.2 Turning space
For example, in kitchens, Section 11B-804.3.1 requires at least one work surface with clear floor space complying with Section 11B-306 to be centered beneath....
-
§ 36.406(e)(1)
(1) Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping...
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
11B-407.4.10.1 Location
Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above the floor of the car....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
605.2 Height and Depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground....
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
Approach
The turning space may overlap the accessible route and the required clear floor space....
-
K. Ambulatory Stall
If there are more than 5 stalls in any restroom, is there one stall in addition to the large accessible stall, that is 36" wide, has 2 parallel grab bars at 33"-36" off the floor and has...
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
Audible Tones/Bells or Verbal Annunciators
...are all of the elevators equipped with audible tones/bells or verbal annunciators that designate the passage of floors?...
-
5. Grab Bars
Does the accessible toilet in each accessible guestroom bathroom have a horizontal grab bar along the wall behind the toilet that is at least 36" long and mounted 33"-36" above the floor...
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
4.10.2 Automatic Operation
Each car shall be equipped with a self-leveling feature that will automatically bring the car to floor landings within a tolerance of 1/2 in (13 mm) under rated loading to zero loading conditions...
-
4.10.2 AUTOMATIC OPERATION
Each car shall be equipped with a self-leveling feature that will automatically bring the car to floor landings within a tolerance of 1/2 in (13 mm) under rated loading to zero loading conditions...
-
4.34.5.5(1) Size and clearances
Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
Knowing audio description is present in the exhibition
A difference in floor texture could be used to cue visitors with vision loss where the panels with description buttons are located....
-
4.27.3* HEIGHT
Except where the use of special equipment dictates otherwise, electrical and communications system receptacles on walls shall be mounted no less than 15 in (380 mm) above the floor....
-
§100.201a(b)(1) ICC/ANSI A117.1-2003
., 6th Floor, Washington, DC 20001-2070, telephone number 1-888-422-7233, http://www.iccsafe.org/e/category.html....
-
§100.201a(b)(2) ICC/ANSI A117.1-1998
., 6th Floor, Washington, DC 20001-2070, telephone number 1-888-422-7233, http://www.iccsafe.org/e/category.html....