Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
Search Results "Ceramic Tile Flooring"
-
11B-404.2.10 Door and gate surfaces
-
1136A.1 Receptacle heights
inches (1219 mm) measured from the top of the receptacle outlet box nor less than 15 inches (381 mm) measured from the bottom of the receptacle outlet box to the level of the finished floor...
-
11B-809.10.7.3 Reinforcement for grab bars
comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The technical requirements address clear floor space, height, faucets, and exposed pipes and surfaces....
-
Outdoor Rinsing Showers
Both showers must meet the clear floor and ground space and outdoor recreation access route requirements that follow....
-
Lift Compatibility (M301.4 and M302.4)
Portable floor lifts have legs with wheels that need to fit under or around the base of the diagnostic equipment....
-
4.1.3 Adjustable Height Chairs with and without Footplates
4.1.3 Adjustable Height Chairs with and without Footplates Patients seated in adjustable height examination chairs typically rest their feet on the floor or on a footplate or have their...
-
How should we describe facilities that only meet some of the accessibility guidelines?
For instance, you can let people know that the main floor of the office is accessible but other floors can be reached by stairway only, and provide instructions on how to visit someone whose...
-
Fire Rings, Grills, Fireplaces, and Wood Stoves
The slope of the clear floor or ground space must not exceed 1:48 (2 percent) in any direction....
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-805.7 Built-in cabinets and work surfaces
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....
-
Picnic Tables
In addition to the clear floor or ground space for each wheelchair seating space, provide a 48-inch (1,220-millimeter) clear floor or ground space around the usable portions of the table...
- Step ‘n Wash Sink Step
- Pressalit Care Adult changing table 3000, electrically height adjustable
-
§ 1194.25(j)(3)
(3) Where any operable control is more than 10 inches and not more than 24 inches behind the reference plane, the height shall be 46 inches maximum and 15 inches minimum above the floor....
-
Mirrors
Provide a mirror in the Spy City Café men's and women's toilet rooms where the bottom edge of the reflecting surface of the mirror is mounted no more than 40" above the finished floor....
-
1b
Do they have a fixed or folding seat between 17"-19" above the floor, onto which a person who uses a wheelchair may transfer to shower?...
-
H27
Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor?...
-
§100.201 Covered multifamily dwellings
Covered multifamily dwellings means buildings consisting of 4 or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units in other buildings consisting...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...