The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
Search Results "Maximum Reach Depth"
-
604.5.1 Side Wall
-
M305.3.1 Horizontal Position
Where the support is horizontal, the top of the gripping surface shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum above the standing surface....
-
M305.3.2 Vertical Position
Where the support is vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high maximum...
-
Do drinking fountains pose hazards as protruding objects?
This is not required for wheelchair accessible units with no more than a 27” clearance below (the minimum required for knee clearance and the maximum recognized for cane detection)....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
11B-809.8.4 Door signal devices
The activating mechanism shall be mounted 48 inches (1219 mm) maximum above the floor and connected to permanent wiring....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
703.5.8 Character Spacing
Spacing between individual characters shall be 10 percent minimum and 35 percent maximum of character height....
-
704.2.1.2 Forward Approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
M302.2.4 Transfer Sides (Section-by-Section Analysis)
transfer side provision for diagnostic equipment used by patients in the seated position required transfer surfaces to have the option to transfer from a mobility device onto one short side (depth...
-
About the Guide’s Author
Her breadth and depth of experience in access and functional needs and her work as a writer, trainer, researcher, policy analyst, and advocate is widely known and respected....
-
Design Criteria for the Transfer Station
Criteria Design Element Dimensions Seat width ranges for platform 1 and 2 Adjustable between 18” and 30” Seat depth...
-
A. Passenger Drop-Off Areas
Access aisle depth is at least 5 feet. 2. Access aisle length is at least 20 feet. 3. [sic] 3....
-
Clear Floor Space [4.16.2]
Space at least 60 inches wide is necessary for side transfers and when provided a 56 inch depth is permitted for either a forward or side approach because of the maneuvering space available...
-
Wheelchair Turning Space [4.2.3]
Generally, the depth of usable floor space below fixed elements with knee and toe clearance is limited to 19 inches....
-
1.1.17 Stairs
Measure cast - in - place stairs for both riser height and tread depth of each riser and tread....
-
407.4.1 Car Dimensions
EXCEPTION: Existing elevator car configurations that provide a clear floor area of 16 square feet (1.5 m2) minimum and also provide an inside clear depth 54 inches (1370 mm) minimum and...
-
1003.3.1 Boat Slip Clearance
Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
Bonded Impact/cushioning Surfaces
Bonded Impact/cushioning Surfaces Eight different surface test specimens were formed with surface dimensions of 1.2m x 1.2m with a depth of 0.3m (48”x48”x 12”) in Madison WI (Figure 1...
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
Sec. 469.001(c)
persons with disabilities and to eliminate, to the extent possible, unnecessary barriers encountered by persons with disabilities whose ability to engage in gainful occupations or to achieve maximum...
-
Disinformation Corridor Exhibit
The force required to push or pull open the red door leading out of the exhibit is 15 lbf, which exceeds the maximum allowable door opening force of 5 lbf....
-
Rising Sun Exhibit
The force required to push or pull open the painted door leading out of the exhibit is 14 lbf, which exceeds the maximum allowable door opening force of 5 lbf....