Ramps and curb ramps, which must be used to span vertical changes greater than ½”, must have level landings and clearances at the tops and bottoms of each run to provide adequate separation...
Search Results "Latch Side Clearance"
-
Is there a minimum distance between changes in level?
-
Protrusion Limits [§307.2]
Those with leading edges that are within cane sweep (27” high maximum) or that provide minimum headroom clearance (80” minimum) do not pose hazards and can protrude any amount....
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
Re: Service Counters
CBC 11B-904.4 does not contain any qualifying language that separates the differing requirements between the employee and customer sides of the counter because this information is contained...
-
Picnic Tables
All new picnic table installations must comply with requirements for accessible seating spaces, table clearance, slope, and surface....
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
6. Clear floor space
Clear floor space: Adequate space is provided to approach the toilet from a variety of wheelchair transfer positions (i.e. diagonal or side approaches)....
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
3. Toilet Centerline
Is the accessible toilet in each accessible guestroom bathroom centered 18" from the adjacent side wall, which is the distance that will permit a person with a mobility impairment to use...
-
12. Reach Range
Are there towel racks or bars placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons who use wheelchairs can approach and use the towel racks...
-
GUARD OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
§ 37.131(a)(1)(i)
(i) The entity shall provide complementary paratransit service to origins and destinations within corridors with a width of three-fourths of a mile on each side of each fixed route....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
Re: Section 307 Protruding Objects
The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...
-
ASME
that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum along the back and sides...
- Pilot Rock BS Series Bike Stand
-
Threshold Height
A maximum height of ½ inch is generally specified, although an exception permits a maximum height of ¾ inch at existing or altered thresholds that have a beveled edge on each side....
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
Housekeeping
Cleaning carts should be placed to the side of the hallways so guests using wheelchairs have space to pass....
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
FAQ: How do I enter ADA references in my Voices post?
Begin to type a section number relevant to your post, for example "308.3" or the section name, for example "side reach."...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...