Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
Search Results "End-Opening Door"
Commonly Searched Documents
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
-
11B-608.5.1 Transfer type shower compartments
mm) minimum and 48 inches (1219 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
Section 36.303(g)(6) Alternative Technologies
Department should require open movie captioning....
- Magnuson Group STORLEK Waste Receptacles
-
§ 36.303(g)(9)(iii)
(iii) Turn on open movie captions if the movie theater is relying on open movie captioning to meet the requirements of paragraph (g)(3) of this section; and...
-
§ 36.303(g)(9)(iii)
(iii) Turn on open movie captions if the movie theater is relying on open movie captioning to meet the requirements of paragraph (g)(3) of this section; and...
-
§ 37.131(a)(2)(ii)
(ii) At end stations and other stations in outlying areas, the entity may designate circles with radii of up to 11/2 miles as part of its service area, based on local circumstances....
-
1007.8 Exterior area for assisted rescue
The exterior area for assisted rescue must be open to the outside air and meet the requirements of Section 1007.6.1....
-
1003.2.13.7 Exterior area for assisted rescue
The exterior area for assisted rescue must be open to the outside air and meet the requirements of Section 1003.2.13.5.1....
-
2010 ADA Standards
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
104.1.1 Construction and Manufacturing Tolerances
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
104.1.1 Construction and Manufacturing Tolerances
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
1133B.2.4.2
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.4 Floor level at doors. ...
-
M301.2.3 Transfer Surface Transfer Sides
The option to transfer will be required only on one long side of the patient scanning/imaging table and not at the “foot” or “head” end of such surfaces....
-
M301.2.3 Size (Section-by-Section Analysis)
discussed in Section IV.B.1.c (Significant Changes – Transfer Surface Size), in the final rule the Access Board has revised this provision to account for the two types of transfer surfaces (end...
-
A.2.ii. - Should EIT be compatible with assistive technology?
These products, such as information kiosks, copiers, or other similar products that do not permit a user to install or connect assistive technology, must be designed so that an end user...
-
Undue Hardship
to six days of intermittent leave for one month, four to six days of intermittent leave each month for six months, leave required indefinitely, or leave without a specified or estimated end...
-
Comparison: 2010 and 1991 ADA Standards for Accessible Design - Scoping Requirements
., Door opening shall provide clear width of 32 inches minimum, Thresholds shall be ½ inch high maximum....
-
M1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door and centered 60 inches above the floor?...
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum. Exceptions: 1. ...
-
1003.3.2 Boarding Pier Clearances
Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
1003.3.2 Boarding Pier Clearances
Every 10 feet (3050 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
11B-106.5 Defined terms
RIDE AMUSEMENT RIDE SEAT ANSI APPROVED APPROVED TESTING AGENCY AREA OF REFUGE AREA OF SPORT ACTIVITY ASSEMBLY AREA ASSISTIVE LISTENING SYSTEM (ALS) AUTOMATIC DOOR...