FOR STANDARD INSTALLATION: Mount at 24” above finished floor to lip of urinal or as required by architect. Center drain line to be at 15.0” above finished floor....
Search Results "Court Floor Holding Cell"
Commonly Searched Documents
- Waterless Co. No-Flush Urinal Anza 2005
- RI Global
-
Sec.36.403(c)(1)(ii)
(ii) Replacing an inaccessible floor surface in the customer service or employee work areas of a bank;...
-
Coin Slot Height
Is it mounted with the coin slot no higher than 54" above the floor? Yes __ No __ N/A __ Comments: ___________________________________________...
-
Handset Reach Range
Is it mounted with the handset cradle no higher than 54" above the floor? Yes __ No __ N/A __ Comments: ___________________________________________...
-
§ 36.403(c)(1)(ii)
(ii) Replacing an inaccessible floor surface in the customer service or employee work areas of a bank;...
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....
-
4.7.9.4 Depth
The bottom of the bowl shall be at least 15 inches (380 mm) above the floor or ground....
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
- Magnuson Group SCOOP Magazine & Literature Displays
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
(c) Thresholds at patio, deck or balcony doors
The final Guidelines provide that exterior deck, patio, or balcony surfaces should be no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed...
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...
-
4.10.13* Car Position Indicators
As the car passes or stops at a floor served by the elevators, the corresponding numerals shall illuminate, and an audible signal shall sound....
-
Raised and Braille Characters on Hoistway Entrances [4.10.5]
Raised and Braille floor designations are required on both jambs, with the centerline 60 inches from the finished floor. Raised characters must be 2 inches high....
-
4.1.3(10)(a)
(a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
4.10.13* CAR POSITION INDICATORS
As the car passes or stops at a floor served by the elevators, the corresponding numerals shall illuminate, and an audible signal shall sound....
-
11B-405.9.2 Curb or barrier
mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...