In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
Search Results "Court Floor Holding Cell"
-
1007.2.1 Buildings with four or more stories
-
1003.2.13.1.1 Buildings with four or more stories
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
Electronic instruments
Electronic instruments have been developed to measure floor flatness....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
§ 38.23(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches or less above a 6-inch curb, a maximum slope of 1:4 is permitted; if the height of the vehicle floor from which...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the...
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
-
§ 36.404(b)
For example, alterations to floors above or below the accessible ground floor must be accessible regardless of whether the altered facility has an elevator....
-
Sec.36.404(b)
For example, alterations to floors above or below the accessible ground floor must be accessible regardless of whether the altered facility has an elevator....
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
Eliminating Hazards [4.26.4]
Extensions must be rounded or returned to the walls, floors, or posts. Extensions with bottom edges within 27 inches of the floor are detectable within the standard sweep of canes....
-
11B-809.1.2 Viewing devices
entry door to a residential dwelling units with mobility features shall also provide a lower viewing device 42 inches (1067 mm) minimum and 43 inches (1092 mm) maximum above the finish floor...
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
-
Where do I measure for a handrail extension?
regardless, the technical question pertains to where on the handrail you should measure as it turns horizontally toward a wall return, or as it turns downward to a guard/post or down to the floor...
-
Fixed Seating and Tables
An accessible table has a surface height of no more than 34 inches and no less than 28 inches above the floor....