II−5.6000 Time periods for achieving program accessibility. Public entities must achieve program accessibility by January 26, 1992. If structural changes are needed to achieve...
Search Results "Residential Facility"
-
II-5.6000 Time periods for achieving program accessibility
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6.
-
11B-810.9 Escalators
Where provided, escalators shall comply with the sections 6.1.3.5.6 and 6.1.3.6.5 of ASME A17.1 and shall have a clear width of 32 inches (813 mm) minimum. Exception: Existing...
-
11B-216.7 Elevators
Where existing elevators do not comply with Section 11B-407, elevators complying with Section 11B-407 shall be clearly identified with the International Symbol of Accessibility...
-
11B-1006.4 Weather shelters
A clear floor or ground space 60 inches (1524 mm) minimum by 96 inches (2438 mm) minimum shall be provided within weather shelters.
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2.
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical...
- Open Doors Organization (ODO)
-
11B-813.1 Location
Adult changing facilities shall be provided within a unisex (single-user or family) toilet room or other similar private room....
-
Minimum Number of Beach Access Routes [F248.2]
Pedestrian access points to a beach include parking facilities, dune crossings, and stairways or ramps leading from boardwalks to the beach....
-
606.2 Clear Floor Space
A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and...
-
606.2 Clear Floor Space
A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and...
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length...
-
11B-809.9.3 Removable base cabinets
Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
-
2. c. REACH RANGES
The maximum reach ranges (detailed below) should be considered in the placement of information brochures, magazines and other items located in medical office lobbies, reception, and...
-
The Inspection Team
If multiple areas of the property will be used or there are any off-site events planned, the inspection team should visit all sites, including any transportation facilities, to ensure they...
-
Architectural Barriers Act
Architectural Barriers Act The Architectural Barriers Act (ABA) requires that buildings and facilities that are designed, constructed, or altered with Federal funds, or leased by a Federal...
-
What occupancies are or are not subject to path of travel and/or accessible routes? …buildings subject to California Building Code (CBC) Chapter 11B? …multi-family buildings subject to CBC Chapter 11A? …others?
RESPONSE: Buildings and facilities required to comply with Chapter 11B, including public housing facilities, are required to comply with the CBC Chapter 11B accessibility provisions for...
-
SECTION 504 OF THE REHABILITATION ACT OF 1973 POLICY INTERPRETATION NO. 3
The regulation does not require that all existing facilities or every part of an existing facility be made accessible; structural changes are not necessary if other methods are effective...
-
Section 35.150(b)(2) Safe Harbor (Section-by-Section Analysis)
The title II regulation makes clear that, unlike public accommodations under title III, a public entity is not required to make each of its existing facilities accessible to and usable by...
- Inclusion Solutions BigBell™ Max Alert System
-
§ 37.43 Alteration of transportation facilities by public entities
[See subsections ...]
-
When do path of travel and/or accessible routes apply? …new construction? …alterations to a parking area? …alterations to a building associated with parking, such as expansion or remodel?
In the new construction of a new facility, all accessible rooms and spaces are required to be connected by an accessible route and all toilet facilities, drinking fountains, public telephones...
-
§ 35.150(b)(2) Safe harbor
If a public entity has constructed or altered elements in an existing facility in accordance with the specifications in either the 1991 Standards or the Uniform Federal Accessibility Standard...