(ii) Replacing an inaccessible floor surface in the customer service or employee work areas of a bank;...
Search Results "Floor Button"
-
§ 36.403(c)(1)(ii)
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....
-
4.7.9.4 Depth
The bottom of the bowl shall be at least 15 inches (380 mm) above the floor or ground....
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
10 - foot straightedge method
10 - foot straightedge method This is the classic method for determining the flatness of concrete and other types of finished floors....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
VII. Existing Facilities: Removal of Barriers
machines, display racks, and other furniture, Widening doorways, Installing grab bars in toilet stalls, and Adding raised letters or braille to elevator control buttons...
-
M307 Operable Parts (Section-by-Section Analysis)
For example, equipment used for an auditory examination may require the patient to press a button when sounds are heard....
-
1. New Format for Guidelines
Advisory sections and figures are included in the documents on our webpage at: www.access-board.gov. 1 The four mandatory symbols are the: symbols to identify elevator control buttons...
-
Hearing Aid Compatible and Volume Control Telephones [4.13.5] [sic]
Most are located in the base and operated by pressing a button or key. Volume controls located in handsets are often used in retrofitting existing phones....
-
F105.2.2 ASME
The communication system must be push button activated. The activation button must be permanently identified with the word "HELP."...
-
Volume Control
In the proposed rule, the Board requested information on the feasibility and cost of equipping new and existing public pay telephones with a mute button and whether such a requirement should...
- Meridian Presenza Family Kiosk
-
413.1 General (Section-by-Section Analysis)
They suggested that either the scoping of the requirement be modified, or “general purpose” devices be exempted from providing physical buttons for closed captions and audio description....