Along with cost and business operation, the technical feasibility of barrier removal must be taken into consideration. It may be impossible to alter or expand a bathroom due to load...
Search Results "Maximum Dimension"
Commonly Searched Documents
-
Technical difficulty and readily achievable
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
Exceptions When Conditions Do Not Permit Full Compliance
The proposed rule would have required compliance “to the maximum extent feasible” when an exception is used....
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
Alterations to Qualified Historic Buildings and Facilities: ADA Standard Section 202.5
Section 202.5 covers the most current ADA Standards for alterations to qualified historic buildings and facilities.
-
202.4 Alterations Affecting Primary Function Areas
to the requirements of 202.3, an alteration that affects or could affect the usability of or access to an area containing a primary function shall be made so as to ensure that, to the maximum...
-
Section 36.402 Alterations (Preamble, Section-by-Section Analysis)
Section 36.402(a)(1) provides that any alteration to a place of public accommodation or a commercial facility, after January 26, 1992, shall be made so as to ensure that, to the maximum...
-
Section 36.402 Alterations (Section-By-Section Analysis and Response to Comments)
Section 36.402(a)(1) provides that any alteration to a place of public accommodation or a commercial facility, after January 26, 1992, shall be made so as to ensure that, to the maximum...
-
Substitute cells. (Section-by-Section Analysis)
., cells other than those where alterations are originally planned), provided that each substitute cell is located within the same facility, is integrated with other cells to the maximum...
-
202.4 Alterations Affecting Primary Function Areas
to the requirements of 202.3, an alteration that affects or could affect the usability of or access to an area containing a primary function shall be made so as to ensure that, to the maximum...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
11B-222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with Section...
-
Issue 9: Reach (how far?)
Issue 9: Reach (how far?) APS devices can be located in landscaped areas if the pushbutton is reachable from a level paved area. Figure 12 shows a location where new APS (and new...
-
F222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with...
-
222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with...
-
222.1 General
222.1 General. Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply...
-
Reach Ranges and Operability Requirements
In this guidebook, you will see the provision "Controls and operating mechanisms must comply with the requirements for reach ranges and operability specified in ABAAS, sections 308...
-
Alterations
In alterations, the minimum number is based on the total number of spaces altered or added to a lot. Recommendation: Where a lot is not fully altered, it is recommended that the...
-
4. I understand that a waiver from accessibility requirements may be obtained?
It is possible that a particular degree of accessibility in an alteration might be found to be an "unreasonable hardship", "disproportionate", or "technically infeasible". Such...
-
4.17.3* Size and Arrangement