Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
Search Results "Door Opening Angle"
Commonly Searched Documents
-
604.8.1.2 Doors
- Sargent 281 Series Cast Iron Door Closer
-
604.8.1.2 Doors
604.8.1.2 Doors....
-
3.3.16 Door Use
WhMD users had more difficulty “Opening” door 3, as compared to doors 1 and 2....
- Yale 5800 Series Cast Iron Door Closer
- TownSteel TDC 40, CAST IRON Grade 1 Door Closer
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
- Corbin Russwin Inc. DC6000 Series Cast Iron Door Closer
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
404.2.8.1 Door Closers and Gate Closers
404.2.8.1 Door Closers and Gate Closers....
-
404.2.4.2 Doorways without Doors or Gates
Sliding Doors, and Folding Doors....
-
4.6.7 Openings
Openings in the clear floor or ground space surface shall not allow passage of a sphere more than 1/2 inch (13 mm) diameter....
- Yale 2700 Series Architectural Door Closer
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
- Stanley QDC 200 Series Grade 1 Heavy Duty Door Closers
- Stanley QDC 300 Series Grade 1 Standard Duty Door Closers
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
- Allegion LCN 1000 Surface Mounted Door Control
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
- Norton Surface Mounted Heavy Duty 9500 Series Door Closer
-
11B-411.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
A4.17.5 DOORS
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...