Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
11B-407.4.8.2.1 Signal type
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
- Hager Companies 5400 Series - Standard Duty Surface Door Closer
- Guldmann GH1 Q Lifting Module
- Bobrick Automatic Foam Dispenser B-8263
- BEA Inc. PBJMS Series Jamb Push Plate (Push to Open)
- Bobrick Automatic Liquid Soap Dispenser B-826
- Pressalit Care PLUS Support Arm Height and Sideways Adjustable Swing Grab Bar
- Mockett TLKNB27 Original Kyros Leg 5" Base
- Pressalit Care PLUS Support Arm Height Adjustable Swing Grab Bar
- Pressalit Care VALUE Support Arm Height Adjustable
- DelAWARE DisABILITIES HUB
-
1132A.4 Level floor or landing
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm)....
-
11B-610.3 Shower compartment seats
The top of the seat shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
- WheelchairJimmy.com
- Midmark 647 Barrier-Free® Power Podiatry Procedures Chair
-
Ground Level Play Components: ADA Standard Section 240.2.1
Section 240.2.1 covers scoping requirements in the current ADA Standards for ground level play components.
-
11B-240.2.1 Ground level play components
Where ramps connect elevated play components, the maximum rise of any ramp run is limited to 12 inches (305 mm)....
-
11B-239.2 Minimum number
If a course is designed with the minimum 50 percent accessible holes, designers or operators are encouraged to select holes which provide for an equivalent experience to the maximum extent...
-
239.2 Minimum Number
If a course is designed with the minimum 50 percent accessible holes, designers or operators are encouraged to select holes which provide for an equivalent experience to the maximum extent...
-
233.3.6
233.3.6 All new single-family houses, duplexes, triplexes, condominiums, and townhouses shall provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided...
-
Mirror Height
The ANSI A117.1‒2003 standard contains a new requirement that specifies a height of 35 inches maximum for accessible mirrors not located above a lavatory or counter top....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....