If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
Search Results "Latch Side Clearance"
Commonly Searched Documents
-
4.8.5* Handrails
-
11B-610.3.1 Rectangular seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall....
- seca 664 - electronic wheelchair scale_without comments - seca1840
- PRL Glass Systems Inc. Panic Device PL-100 Series
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
4.7.11 Islands
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long between the curb ramps in the part...
-
§ 38.113(a)(1)
(1) At least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this part...
- Greenfields Outdoor Fitness Two-Person Accessible Combo Butterfly and Reverse Fly GR2005-1-48E-W (2 Configurations)
-
11B-904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
G. Compartment Size
.: diagonal or side approaches)? [ADA Stds. 4.17.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
R207.1 General
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
Design Opportunity
The pictured example vanity using the stock bracket and dimensions shown in section view may not provide the required minimum 8" deep knee clearance at 27" AFF under the vanity top (306)...
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
403 Walking Surfaces
The requirements for walking surfaces derive from existing specifications for accessible routes covering floor or ground surfaces, slope, changes in level, and clearances....
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
-
11B-410.1 General
Because an accessible route requires an 80 inch (2030 mm) vertical clearance, care should be taken in selecting lifts as they may not be equally suitable for use by people using wheelchairs...
- Salsbury Industries Solid Oak Executive Wood Locker Double Tier 1 Wide
- Salsbury Industries Solid Oak Executive Wood Locker Double Tier 3 Wide
- Salsbury Industries Solid Oak Executive Wood Locker Triple Tier 1 Wide