Aisles between post office boxes shall be a minimum of 66 in (1675 mm) clear width....
Search Results "Swing Clear Hinge"
Commonly Searched Documents
-
9.4 POST OFFICE BOXES
-
Size [§304.3]
access, locate elements with knee and toe space outside the turning space or, with circular space, limit overlap to approximately 12” so that wheelchair space 48” long minimum remains clear...
-
1.2.1
1.2.1 Use the plus - or - minus symbol (±) after a dimension when it must be made clear what the expected tolerance is. This should be coordinated with the specification requirements....
- Bradley Plastic Baby Changing Station
- ASI Storage Solutions Angle Frame Locker
- Hussey Seating Company Roll-A-Way Seating
- AJW Architectural Products U6054 Unidoor Folded Towel Dispenser & Waste Receptacle Combination - Recessed
- AJW Architectural Products U646 Series Lever Operated Roll Towel Dispenser & Waste Receptacle Combination - Recessed
- AJW Architectural Products U6014 Unidoor Folded Towel Dispenser & Waste Receptacle Combination - Recessed
- AJW Architectural Products U2334 Unidoor C-fold/Multifold Towel Dispenser - Recessed
- AJW Architectural Products U650 Series C-fold/Multifold Towel Dispenser & Waste Receptacle Combination w/ Extended Waste - Recessed
- Wisconsin Bench Manufacturing ADA Locker Benches
- Besam SL500 Telescopic Automatic Sliding Door
- HEWI Range 130 Door Hardware
- Interface Silver Linings Collection SL930 Carpet Tiles
-
G. Women's Spa and Fitness Center Locker Room
Clear space sufficient to allow a person using a wheelchair to make a parallel transfer onto the bench will be provided. 2010 Standards §§ 222.1, 305, 803.4, and 903....
-
Executive Order 12866
The ADA states, ‘‘[i]t is the purpose of this [Act] (1) to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities;...
- Norton Surface Mounted Heavy Duty 9500 Series Door Closer
-
8 [§§ 4.3.3; 4.3.7]
8 [§§ 4.3.3; 4.3.7] Curb ramps should have at least 36 inches of clear space at the “top” of the ramp, which can be seen in the illustration to the right [below]....
-
608.2.1 Transfer Type Shower Compartments
Transfer type shower compartments shall be 36 inches (915 mm) by 36 inches (915 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (915...
-
Wheelchair Storage Space
Operators are not required to provide a constructed element or lockers for storage, only a clear space....
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
18.1 Q. Is it necessary to provide usable doors when the door leads to an area of the dwelling that is not accessible, such as the door leading down to an unfinished basement...?
Such doors would have to provide at least 32 inches nominal clear width when the door is open 90 degrees, measured between the face of the door and the stop....