EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
Search Results "Exception"
-
410.6 Doors and Gates
-
207.1 General
EXCEPTIONS: 1....
-
804.3.1 Clear Floor or Ground Space
EXCEPTION: Cabinetry shall be permitted under the kitchen work surface provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement...
-
505.10 Handrail Extensions
EXCEPTIONS: 1. Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg stairs and ramps. 2....
-
604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
904.4.1 Parallel Approach
EXCEPTION: Where the provided counter surface is less than 36 inches (915 mm) long, the entire counter surface shall be 36 inches (915 mm) high maximum above the finish floor....
-
407.2.2.2 Visible Signals
EXCEPTIONS: 1. Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2....
-
407.4.6.1 Location
EXCEPTIONS: 1....
-
604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
902.1 General
EXCEPTION: Dining surfaces and work surfaces for children’s use shall be permitted to comply with 902.4. Advisory 902.1 General....
-
703.4.1 Height Above Finish Floor or Ground
EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1....
-
1008.4.3 Play Tables
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
609.3 Spacing
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1 1/2 inches (38 mm) minimum....
-
608.7 Thresholds
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would...
-
407.2.2.1 Visible and Audible Signals
EXCEPTIONS: 1....
-
403.5.2 Clear Width at Turn
EXCEPTION: Where the clear width at the turn is 60 inches (1525 mm) minimum compliance with 403.5.2 shall not be required. Figure 403.5.2 Clear Width at Turn...
-
207.1 General
EXCEPTIONS: 1....
-
216.11 Check-Out Aisles
EXCEPTION: Where all check-out aisles serving a single function comply with 904.3, signs complying with 703.7.2.1 shall not be required....
-
216.10 Assistive Listening Systems
EXCEPTION: Where ticket offices or windows are provided, signs shall not be required at each assembly area provided that signs are displayed at each ticket office or window informing patrons...
-
307.4 Vertical Clearance
EXCEPTION: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground. Figure 307.4 Vertical Clearance...
-
11B-224.7 Housing at a place of education
Exception: Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or...
-
General: ADA Standard Section 223.1
Section 223.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for medical care and long-term care facilities.
-
General: ADA Standard Section 222.1
Section 222.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for dressing, fitting, and locker rooms.
-
907.5.2.3.1 Public use areas and common use areas
Exception: Where employee work areas have audible alarm coverage, the notification appliance circuits serving the employee work areas shall be initially designed with not less than 20-percent...