Exceptions: 1. ...
Search Results "Exception"
Commonly Searched Documents
-
11B-1008.2.4.2 Elevated
-
604.6 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2. Advisory 604.6 Flush Controls....
-
Q26. When might a service dog's presence fundamentally alter the nature of a service or program provided to the public?
However, there are some exceptions. ...
-
Overview of FSTAG Implementation Process
Now that you have learned about the extent of application, general exceptions, and the technical requirements, you may wonder how the whole process ties together....
-
229 Windows
Exceptions: 1. Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2....
-
3.1.4.2 Width of RV Campsite and Dump Station Vehicle Parking Areas
Exception....
-
604.4 Seats
EXCEPTIONS: 1....
-
6.1 Priority List
projects where full compliance of the path of travel elements cannot be required, based on the disproportionate cost limitation or a determination of unreasonable hardship, Section 11B-202.4, Exception...
-
What requirements of the standards apply in an alteration?
Altered elements or spaces must comply with relevant provisions of the standards except where compliance is technically infeasible....
-
Handrails [§405.8, §505]
The Standards do not require lower handrails serving children except at ramps serving play areas, but include a recommended height (28” max.) and separation (9” min.) from the required handrail...
-
11B-407.2.2.3 Audible signals
Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2. Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals....
-
11B-207.1 General
Exceptions: 1....
-
11B-812.6 Vehicle spaces
Exceptions: 1....
-
11B-211.3 More than minimum number
Exception: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-1008.2.4.2 Elevated
Exceptions: 1....
-
11B-707.3 Operable parts
Exceptions: Drive-up only automatic teller machines and fare machines shall not be required to comply with Sections 11B-309.2 and 11B-309.3....
-
11B-705.1.1.3 Color and contrast
Exceptions: 1....
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
11B-211.3 More than minimum number
Exception: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
11B-228.1 General
Exception: Drive-up only depositories shall not be required to comply with Section 11B-309. Advisory 11B-228.1 General....
-
11B-407.2.2.3 Audible signals
Exceptions: Reserved. Reserved. [2010 ADA Standards] 2....
-
11B-308.3.1 Unobstructed
Exceptions: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum....
-
11B-705.1.2.3 Islands or cut-through medians
Exception: Detectable warnings shall be 24 inches (610 mm) minimum in depth at pedestrian islands or cut-through medians that are less than 96 inches (2438 mm) in length in the direction...