An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
Search Results "Transfer Side"
Commonly Searched Documents
- 
    
  
  1010.2.13.1 Delayed egress locking system
  
 - 
    
  
  11B-404.2.10 Door and gate surfaces
  
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
 - Bosch 3-Point Self-Leveling Alignment Laser GPL 3
 - 
    
  
  2.3 Implications of MDE Accessibility for Clinical Staff
  
Chen, MD, described a failed attempt to transfer a patient onto a fixed height table, capturing the consequences both for the patient and what became the transfer crew – a physician, medical...
 - 
    
  
  6.2 Presentations that Informed the Minimum Height Deliberations
  
Informed the Minimum Height Deliberations As described in Section 3.3, Advisory Committee members considered several different types of evidence in their deliberations about the minimum transfer...
 - 
    
  
  Plan 3A: 12-Foot Wide Accessible Guest Room
  
clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side...
 - 
    
  
  Plan 1A: 13-Foot Wide Accessible Guest Room
  
clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side...
 - 
    
  
  Plan 2A: 13-Foot Wide Accessible Guest Room
  
clearance at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side...
 - 
    
  
  Plan 2B: 13-Foot Wide Accessible Guest Room
  
• Alternate roll-in type shower with folding seat is 36 inches deep and 60 inches wide (section 608.2.3); • Alternate roll-in shower has a 36-inch wide entry at one end of the long side...
 - 
    
  
  1129B.3, Item 2
  
One in every eight accessible spaces, but not less than one, shall be served by a loading and unloading access aisle 96 inches (2438 mm) wide minimum placed on the side opposite the driver's...
 - 
    
  
  Floor Naming and Numbering
  
This is a little abstract one, but if you look at those elevator buttons, whether you’re in a building in San Francisco and you come in on the east side of the building and it’s Floor Level...
 - 
    
  
  D) Curb Ramps at Intersections
  
This type of curb ramp has flared sides and must be used when pedestrians may enter or exit the curb ramp from the side....
 - 
    
  
  2. Typical Issues for Individuals Who Are Blind or Have Low Vision
  
Typical Issues for Individuals Who Are Blind or Have Low Vision Objects that are wall mounted, that project into a pedestrian route from the side, or that are overhead can be hazards...
 - 
    
  
  11B-403.5.1 Clear width
  
The clear width for aisles shall be 36 inches (914 mm) minimum if serving elements on only one side, and 44 inches (1118 mm) minimum if serving elements on both sides. 5. ...
 - 
    
  
  IBC Comparison
  
Justice's Standards for Accessible Design* (column 2), which are based on the original ADA Accessibility Guidelines, and the International Building Code** (column 3) are reordered for side-by-side...
 - 
    
  
  Part 2. Typical Issues for Voters Who Are Blind or Have Low Vision
  
Typical Issues for Voters Who Are Blind or Have Low Vision Objects that are wall-mounted, that project into a pedestrian route from the side, or that are overhead must be located so that...
 - 
    
  
  11B-705.1.2.3 Islands or cut-through medians
  
pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches (51 mm) maximum on each side...
 - 
    
  
  Overlapping Clear Floor Space
  
The Board has clarified that accessible lavatories are permitted to overlap clear floor space "opposite the shower compartment side where shower controls are positioned or where a seat is...
 - 
    
  
  11B-406.5.12 Detectable warnings
  
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
 - 
    
  
  M303.2.6 Edge Protection (Section-by-Section Analysis)
  
requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection, measured from the surface of the platform, on each side...
 - 
    
  
  Detailed Age Demographics
  
For phase 2 there is a small gap in the distribution around 25-35 years old causing the distribution on either side to be greater (Figure D2). Table D2....
 - 
    
  
  25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
  
Figure 2(c) of the Guidelines is illustrating the maximum side reach range over an obstruction....
 - 
    
  
  Handrails [§405.8, §505]
  
Handrails [§405.8, §505] Handrails are required on both sides of ramps with a rise greater than 6”....
 - 
    
  
  11B-406.5.12 Detectable warnings
  
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...