[ADA Standards § 4.6.5] Yes No If No: Can the route be cleared by removing or raising low objects, or can each van accessible parking space be relocated?...
Search Results "Swing Clear Hinge"
Commonly Searched Documents
-
B4
-
1134A.8, Item 4.3
The clear floor space required by Item 2 shall not extend into the knee and toe space more than 19 inches (483 mm). (See Figure 11A-9D)....
-
4.13.6 Maneuvering Clearances at Doors
The floor or ground area within the required clearances shall be level and clear....
-
Side Approach
Recommendation: The clear floor space should be centered on the ATM unit....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
The American Dream
The American Dream The time has come for the Senate to send a loud, clear message across this country: Individuals with disabilities, no less than all other Americans, are entitled to...
-
4.34.6.6* RANGES AND COOKTOPS
The clear floor space may overlap the knee space, if provided, by 19 in (485 mm) maximum. The location of controls for ranges and cook-tops shall not require reaching across burners....
-
1134A.8, Item 4.3
The clear floor space required by Item 2 shall not extend into the knee and toe space more than 19 inches (483 mm). (See Figure 11A-9D)....
-
Are closet doors and pantry doors required to comply?
pantries, cabinets and other storage elements not providing user passage do not have to comply with provisions for doors, but must meet requirements for storage (§811), including those for clear...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
- AJW Architectural Products U2314 Unidoor C-fold/Multifold Towel Dispenser - Recessed
- AJW Architectural Products U2304 Unidoor C-fold/Multifold Towel Dispenser - Recessed
- AJW Architectural Products U2324 Unidoor C-fold/Multifold Towel Dispenser - Recessed
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
Video remote interpreting (VRI) services. (Section-by-Section Analysis)
NPRM, the Department proposed the inclusion of four performance standards for VRI (which the NPRM termed video interpreting services (VIS)), for effective communication: (1) High-quality, clear...
-
Gurney Accessible Bathroom
Movable wall for shower gurney access Vanity remodeled to clear the space for wheelchair users Hand-held shower 6’ hose on shower Shower heads at four...
-
11B-608.2.1 Transfer type shower compartments
Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
-
11B-406.5.10 Diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
Re: 405 Ramps
Gentlemen/Ladies: While the code requires a 60"x 60" clear landing, does it have to be square? Please see attached and advise, thank you....
-
1009.5.2 Transfer Space
Figure 1009.5.2 Clear Deck Space at Transfer Platform...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-220.1.2 Two automatic teller machines or fare machines
machines or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear...
-
Passing Spaces (R302.4) (Section-by-Section Analysis)
Passing Spaces (R302.4) (Section-by-Section Analysis) Where the clear width of pedestrian access routes is less than 1.5 meters (5 feet), passing spaces must be provided at intervals...