purposes of this Consent Order, shall mean and refer to a view to the screen that is not blocked or interfered with by any seats, railings, or other objects and is configured to have visual clearance...
Search Results "Hinge Side Clearance"
-
1.17 Unobstructed view
-
7. Lavatory
Is the lavatory (wash basin) in each accessible guestroom bathroom no more than 34" high with at least 29" high clearance under the front edge to allow persons who use wheelchairs to pull...
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
- Murdock Manufacturing Grab Bars
- EZ-ACCESS Suitcase Singlefold Ramp
- Adaptive Access
-
M302.3.1 Transfer Supports
Transfer supports shall be provided for use with transfer sides required by M302.2.4 and shall comply with M305.2.1.1, M305.2.2.1, and M305.2.3 through M305.2.8....
-
End Transfer Surface
A transfer surface located at one end of an examination surface that allows patient transfer at the end and one adjoining side of the examination surface....
-
R407.9 Edge Protection
Edge protection complying with R407.9.1 or R407.9.2 shall be provided on each side of ramp runs and ramp landings....
-
M8
Is there at least 18 inches between the center of the toilet and the side of the adjacent lavatory? [ADA Standards § 4.16.2; Fig. 28] Yes No...
-
H20
Is the flush valve located on the wide side adjacent to the lavatory or is an automatic flush valve provided? [ADA Standards § 4.16.5] Yes No...
-
e-i
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
4.9.4 Handrails
Stairways shall have handrails at both sides of all stairs. Handrails shall comply with 4.26 and shall have the following features:...
-
4.1.6(3)(d)(ii)
(ii) If existing thresholds are 3/4 in high or less, and have (or are modified to have) a beveled edge on each side, they may remain....
-
802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus....
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus....
- Swan Barrier-Free Folding Shower Seat BF-2300
-
Shower and Sauna Doors in Transient Lodging Facilities
The exemption to the section 224.1.2 requirement for a 32-inch wide clearance at doors to shower and saunas applies only to those showers and saunas in guest rooms which are not required...
-
11B-410.6 Doors and gates
Side doors and gates shall provide a clear width 42 inches (1067 mm) minimum....
-
604.6 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2. Advisory 604.6 Flush Controls....
-
3.1.4.2 Width of RV Campsite and Dump Station Vehicle Parking Areas
Where a double camping unit or dump station is provided to accommodate two RVs or trailers side-by-side in a vehicle parking, the total width of the vehicle parking area may be reduced from...