Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
Search Results "Ramp Width"
Commonly Searched Documents
-
Doors and Gates in Series [§404.2.6]
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
If automated, such doors or gates are required to comply only with provisions for clear width and thresholds, as well as applicable provisions of the referenced ANSI/BHMA Standards....
-
§ 38.23(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch in width....
-
11B-810.5.3 Platform and vehicle floor coordination
operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192 or 49 CFR part 38, mini-high platforms, car-borne or platform-mounted lifts, ramps...
-
Accessible Drop-Off and Pick-Up Areas
Curb ramps must be provided if the drop-off area is next to a curb....
-
Readily Achievable Barrier Removal
Readily achievable barrier removal may include providing an accessible route from a parking lot to the business’s entrance, installing an entrance ramp, widening a doorway, installing accessible...
-
What materials may satisfy ADAAG requirements?
there is a choice between flooring materials otherwise suitable for a particular application, we recommend choosing the material with the higher coefficient of friction, particularly for ramps...
-
11B-235.2.1 Dispersion
The term "boat slip" is intended to cover any pier area other than launch ramp boarding piers where recreational boats are moored for purposes of berthing, embarking, or disembarking....
-
1009.1 Accessible means of egress required
In assembly areas with ramped aisles or stepped aisles, one accessible means of egress is permitted where the common path of egress travel is accessible and meets the requirements in Section...
-
R309.5.1 Location
Locating parking meters at the head or foot of the parking space permits deployment of a van side-lift or ramp or the vehicle occupant to transfer to a wheelchair or scooter....
-
Special Technical Provisions for Alterations to Existing Buildings and Facilities [4.1.6(3)]
Section 4.1.6(3) recognizes certain allowances where technical feasibility is encountered, such as steeper slopes for short ramps....
-
F. Swimming Pool Entrance and Deck
(4) The swimming pool deck ramp, which has an intermediate ramp landing area that is 37 ½ inches long, rather than the required 60 inches, will be supplemented by a platform lift at...
-
Power Wheelchairs
They often cannot be folded or disassembled for transport, so a ramp or lift-equipped van is required....
-
Design of Shared Use Paths, Street Intersections, and Midblock Crossings
Width C. Shoulders and Sideslopes 1. Width and Slope of Shoulders 2. Horizontal Clearance to Obstructions 3. Sideslopes D. (Traffic) Barriers and Railings E....
-
ADA Requirements
And, the Standards require doors with 32 inches of clear passage width, ramps and curb cuts for persons who use wheelchairs, crutches, and other mobility aids....
-
F206.7.9 Team or Player Seating
While the use of platform lifts is allowed, ramps are recommended to provide access to player seating areas serving an area of sport activity....
-
§382.95(b)
(b) As a carrier, you must, except as otherwise provided in this subpart, provide boarding and deplaning assistance through the use of lifts or ramps at any U.S. commercial service airport...
-
206.7.9 Team or Player Seating
While the use of platform lifts is allowed, ramps are recommended to provide access to player seating areas serving an area of sport activity....
-
1.1.3
1.1.3 A maximum overall design running slope for exterior accessible surfaces (other than ramps), such as sidewalks, of 4% (approximately 1:25) is recommended....
-
A. Accessible Voting Program
condition on Election Day those features of facilities and equipment (including, but not limited to, permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps...
- Harmar CPL800H-1400H Hydraulic CPL with Modular Tower
-
Pemko 193 Slip resistance
By slip resistance I am assuming it will meet the coefficient of friction requirement of 0.8 if installed on a ramp. Thank you -Brian...
-
Accessible routes
Accessible routes that coincide with, or are located in the same area, as general circulation paths and elements such as ramps, elevators, and fare vending and collection must be placed...
-
11B-809.7.2 Changes in level
Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with Section 11B-410 shall be provided where changes in level exceed 1/2 inch (...