Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 206.7.5 Existing Site Constraints....
Search Results "Ramp Width"
-
206.7.5 Existing Site Constraints
-
11B-244.1 General
The CBC requires raised areas of the facility to provide access by ramp, special access lift or elevator....
-
1009.2.1 Elevators required
installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required as part of the accessible means of egress on floors or occupiable roofs provided with a ramp...
-
11B-244.1 General
The CBC requires raised areas of the facility to provide access by ramp, special access lift or elevator....
-
1011.4, Item 2
Each exit door that is required to comply with Section 1011.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
T402.8.1 Deployment to Roadways or to Curb Height Boarding and Alighting Areas
The running slope of ramps and bridgeplates used for deployment to the roadway or to curb-height boarding and alighting areas shall be 1:6 maximum, as measured to ground level with the non-rail...
-
1013.4, Item 2
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
§ 37.165(f)
(f) Where necessary or upon request, the entity's personnel shall assist individuals with disabilities with the use of securement systems, ramps and lifts....
-
§ 38.81(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the...
-
i) Grievance Procedures
City's grievance procedure.22 At trial, Kirola testified to having made a single request for the removal of an access barrier; namely, her July 2006 request that the City install curb ramps...
-
III-4.4300 Standards to apply
Are portable ramps permitted? Yes, but only when the installation of a permanent ramp is not readily achievable....
-
Where Platform Lifts are Permitted [§206.7]
recreational boating facilities, and fishing piers and platforms They also are permitted in new construction where topography or other existing exterior site constraints make a ramp...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
B. Accessible Routes To All Service/Activity Areas
Yes ___ No ___ Number of Steps: _______ If No, is there a ramp, lift, or elevator? Yes ___ No ___ Type of device: _______ B1-b....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
F240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
Two Step Transfer Evaluation
The two-step transfers consisted of an adjacent transfer (no gap between two steps) and a ramped transfer over a constant 8 inch gap between two steps....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
11B-240.2.1 Ground level play components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
240.2.1 Ground Level Play Components
A ramp or transfer system to the top of the slide is not required. Where a sand box is provided, an accessible route must connect to the border of the sand box....
-
1003.3.1 Boat Slip Clearance
In existing piers, clear pier space shall be permitted to be located perpendicular to the boat slip and shall extend the width of the boat slip, where the facility has at least one boat...
-
R308.1 Transit Stops
Where security bollards are installed at transit stops, they must not obstruct the clear space at boarding and alighting areas or reduce the required clear width at pedestrian access routes...
-
4.34.6.5(1)
The total width of sink and counter area shall be 30 in (760 mm)....