Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991...
Search Results "Ramp Width"
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
-
11B-502.6.3 Location
Signs shall be permanently posted either immediately adjacent to the parking space or within the projected parking space width at the head end of the parking space....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-307.4.1 Guy braces
Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
-
404.2.4 Maneuvering Clearances
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance....
-
11B-502.6.3 Location
Signs shall be permanently posted either immediately adjacent to the parking space or within the projected parking space width at the head end of the parking space....
-
11B-502.6.3 Location
Signs shall be permanently posted either immediately adjacent to the parking space or within the projected parking space width at the head end of the parking space....
-
B8. Accessible Route
Does an accessible route connect the curb ramp to the accessible entrance? [ADA Stds 4.1.2(1)]...
- Harmar CPL400P Portable Vertical Platform Lift
-
M302.2 Transfer Surface
M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width...
-
Suggestion by Eldon Tipping
Eldon Tipping As published in Concrete Construction magazine, September 1998, Eldon Tipping made suggestions for a specification for sloped random - traffic floors such as parking decks, ramps...
-
4. Grievance Procedure
Curb ramp requests submitted through the City's grievance procedure trigger an investigation by DPW....
-
11B-303.3 Beveled
Changes in level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL...
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have ramps, bridgeplates or lifts, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the edge of the ramp, bridgeplate...
-
303.3 Beveled
Changes in level exceeding ½ inch (13 mm) must comply with 405 (Ramps) or 406 (Curb Ramps). Figure 303.3 Beveled Change in Level...
-
M301.2.3.1 End Transfer Surface
EXCEPTION: Transfer surfaces for imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination...
-
M301.2.3.2 Side Transfer Surface
EXCEPTION: Transfer surfaces for imaging equipment with bores shall be permitted to be 21 inches (535 mm) wide minimum but shall not be permitted to be less than the full width of the examination...
-
404.2.4 Maneuvering Clearances
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance....
-
Transfer Steps
Each transfer step must have a tread depth of 14 inches minimum to 17 inches maximum and a minimum tread width of 24 inches....
-
Technical Requirements [1018 and 1018.1, Exception 3]
The technical requirements for beach access routes include specific provisions for connections, the surface, clear width, obstacles, openings, running slope, cross slope, resting intervals...
-
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position The issues were discussed and decided in the full committee meeting as follows: depth of 17 inches minimum and width...
-
7.4.11.1 Clear Space
The clear space shall not overlap the trail width but may overlap a resting space or passing space. The slope of the clear space shall not exceed 1:20 (5 percent) in any direction....
-
4.34.6.5(7)
The knee space shall have a clear width of 30 in (760 mm) and a clear depth of 19 in (485 mm)....
-
2.6 Passing Spaces
ORARs with a clear width less than 60 inches (1525 mm) shall provide passing spaces complying with 2.6 at intervals of 200 feet (61 m) maximum....