5.2.2.2 Transfer Surface Depth Recommendation for M302 The Committee recommends a minimum depth requirement of 17 inches for equipment used by patients in seated positions....
Search Results "Patient in Side-Lying Position"
Commonly Searched Documents
-
5.2.2.2 Transfer Surface Depth Recommendation for M302
-
5.2.2.1 Transfer Surface Width Recommendations for M302
Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily used by patients...
- Hill-Rom Viking® M Patient Lift
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. ...
-
M303 Diagnostic Equipment Used by Patients in a Wheelchair (Section-by-Section Analysis)
M303 in the final rule establishes the technical requirements for diagnostic equipment used by patients seated in a wheelchair, such as weight scales with wheelchair spaces and mammography...
- Hoyer Advance-H Patient Lift
- Hill-Rom Golvo® 8000 / 8008 Patient Lift
-
M302.2 Transfer Surface
M302.2 Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one short...
-
5.9.1 Standing Supports In Reference To Mammography Equipment
To be useful, positioning supports must be shaped for grasping, positioned within reach range of all users, and be 12 inches long minimum when located on the moving C-arm or 18 inches long...
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2....
-
Shooting Facilities with Firing Positions: ADA Standard Section 1010
[See subsections ...]
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
- Hill-Rom Uno™ 102 Patient Lift
-
Hill-Rom Viking® M Patient Lift
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Using Patient Lifts
Using Patient Lifts Medical providers may need a lift in order to transfer some patients safely onto an exam table....
-
11B-1010 Shooting facilities with firing positions
[See subsections ...]
-
11B-243 Shooting facilities with firing positions
[See subsections ...]
-
11B-308.3 Side reach
[See subsections ...]
-
b. Transfer Surface Location
The MDE NPRM proposed the same location and transfer sides of the transfer surface for diagnostic equipment used by patients in the supine, prone, or side-lying position (M301) and diagnostic...
-
11B-703.3.2 Position
Braille shall be positioned below the corresponding text in a horizontal format, flush left or centered. If text is multi-lined, Braille shall be placed below the entire text....
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....