Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
Search Results "Forward Approach"
-
Location: ADA Standard Section 407.4.6.1
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
Access to Approach, Enter, and Exit Work Areas
Access for “approach, entry, and exit” requires a connecting accessible route to the work area and a compliant entrance, including entry doors or gates, plus wheelchair space in the work...
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
4.32.3 Knee Clearances
If seating for people in wheelchairs is provided at tables or counters, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided (see...
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall...
-
Parallel Approach to Kitchen Sinks
Commenters recommended that a parallel approach should be allowed at kitchen sinks in spaces without a cook top or conventional range, consistent with the ANSI A117.1 standard....
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
Table 407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach Reach Depth Operable Part Height Less than 20 inches (510 mm) 48 inches...
- Access Board: Clear Floor Space Position
-
407.8.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches...
-
407.12.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches...
-
305.7.2 Parallel Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm)....
-
Forward Reach [4.2.5]
Forward reaches are measured to the edge of available clear floor space. This accommodates high and low reaches and assumes some forward bending....
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
-
904.4.1 Parallel Approach
904.4.1 Parallel Approach. A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
305.7.2 Parallel Approach
Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach...
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
The clear floor or ground space shall be positioned for a parallel approach to the space dedicated to a refrigerator/freezer with the centerline of the clear floor or ground space offset...